Schneider LTMR100EBD 5100A 24VDC Smart Relay
Last unit- Code
- WS4176
- GTIN
- 3389119404914
- Category
- Special relays
- Dispatch
- Within 1 business day for in-stock items.
- Top seller on Mercado Livre and eBay
- Business invoicing available
- Dispatch within 1 business day
- Secure payment
Choose the buyer type - we open the form with this product already filled in.
Main item details
- Brand
- SCHNEIDER
- SKU / Internal code
- WS4176
- GTIN
- 3389119404914
- Product type
- Special relays
- Condition
- Condition shown in specs
- Stock
- Last unit
- Brand
- SCHNEIDER
- Model
- LTMR100EBD
- Logic input
- Current state 1 guaranteed
- Logic input
- maximum output switching frequency
- Date
- 04/17/2024
- Weight
- 0.46 kg
- Measurements
- 10X15X24
- Locator
- A1P2B
About this item
USED product out of the manufacturer's box
Brand: SCHNEIDER
Model: LTMR100EBD
A smart relay is an advanced version of a conventional relay that includes additional control, monitoring, and communication features. These additional features allow the smart relay to perform more sophisticated functions and offer greater automation and integration capabilities with other systems.
They are widely used in electrical power distribution systems, industrial automation, power monitoring and control systems, among other applications where advanced control, monitoring, and protection functionalities are required.
TESYS T ETHERNET SMART RELAY 5100A 24VDC LTMR100EBD
TeSys T is a motor management system that provides comprehensive motor monitoring, control, and protection when used with short-circuit protection and a contactor. TeSys T manages the most critical processes, reducing downtime and increasing productivity. TeSys T is a flexible system that seamlessly integrates into your automation system via five main communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power across a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages three-phase current measurement via integrated current transformers from 0.4 to 100 A or up to 810 A via external current transformers. It also measures earth current with internal or external earth sensors, motor temperature, and inputs and outputs for various motor control modes, management of detected faults, and other functions. The Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs, and one relay output for signaling detected fault overload relay.
Device short name
Product or component type
Motor controller
Device application
Equipment monitoring and control
Measuring current
Rated supply voltage [Us]
Current consumption
supply voltage limits
20.4…26.24 V DC
Communication port protocol
Modbus TCP / Ethernet / IP
Ethernet IEEE 802.3 interface Addressing 0...159, Transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs
[Ui] rated insulation voltage
690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage
6 kV current or voltage measuring circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
short-circuit resistance
100 kA conforming to EN/IEC 60947-4-1
associated fuse rating
4 A gG for Output
0.5 A gG for control circuit
Protection type
Thermal overload protection
Earth leakage protection
Reverse polarity protection
Overload (time)
Power factor variation
Phase imbalance
Load fluctuation
Thermal protection
Network type and machine diagnostics
Fault recording
Trip context information
Waiting time after overload trip
Trip history information
Operating hours / operational time counter
Motor control command recording
Starting current and time
Phase and earth fault odometers
Event recording
Remaining operational time before overload trip
number of logic inputs
Current state 0 guaranteed
Logic input: Current state 1 guaranteed
Logic input: maximum output switching frequency
5 A at 250 V AC of logic output
5 A at 30 V DC of logic output
admissible power
480 VA (AC-15), Ie = 2 A, 500000 cycles (Output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (Output)
maximum operating rate
contact type and composition
1 NO + 1 NC fault signal
measurement type
Iavg average current
Earth fault current
I1 phase current, I2, I3 RMS
Current unbalance
measurement accuracy
5...15 % internal earth fault current measurement
1 % Voltage (100...830 V)
3 % Power factor
5 % external earth fault current measurement
+/- 30 min/year internal clock
0.02 Temperature
5 % active and reactive power
Overvoltage category
Date: 04/17/2024
Weight: 0.460Kg
Measurements: 10X15X24
Dear customers, if the material is intended for resale, the ST (Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment is exclusively the buyer's.
Cabo Eletro Comercial LTDA thanks you.
5 reasons to buy from Cabo Eletro
- 01 Proven reputation Top seller on Mercado Livre and eBay, with a public sales history.
- 02 Traceability and invoicing Business invoicing and electronic invoices are available for purchases.
- 03 Hard-to-find inventory 12,000+ SKUs, including discontinued and replacement items.
- 04 Fast dispatch In-stock items ship within 1 business day after confirmation.
- 05 Technical support We help validate the code and application before purchase.
Buying multiple items? Request an email quote
Send this item with other codes or SKUs and receive a consolidated quote with invoice details and volume conditions. We support individual buyers, companies, and international buyers.
Em caso de revenda, entre em contato antecipadamente para consultar valores referentes à Substituição tributária.
Verifique na descrição abaixo o estado do item anunciado. Por lá é indicado se o item é novo, usado e todas as outras informações que o comprador precisa saber antes de realizar a compra.
SCHNEIDER LTMR100EBD 5100A 24VDC Smart Relay
USED product out of the manufacturer's box
Brand: SCHNEIDER
Model: LTMR100EBD
A smart relay is an advanced version of a conventional relay that includes additional control, monitoring, and communication features. These additional features allow the smart relay to perform more sophisticated functions and offer greater automation and integration capabilities with other systems.
They are widely used in electrical power distribution systems, industrial automation, power monitoring and control systems, among other applications where advanced control, monitoring, and protection functionalities are required.
TESYS T ETHERNET SMART RELAY 5100A 24VDC LTMR100EBD
TeSys T is a motor management system that provides comprehensive motor monitoring, control, and protection when used with short-circuit protection and a contactor. TeSys T manages the most critical processes, reducing downtime and increasing productivity. TeSys T is a flexible system that seamlessly integrates into your automation system via five main communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power across a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages three-phase current measurement via integrated current transformers from 0.4 to 100 A or up to 810 A via external current transformers. It also measures earth current with internal or external earth sensors, motor temperature, and inputs and outputs for various motor control modes, management of detected faults, and other functions. The Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs, and one relay output for signaling detected fault overload relay.
Main
range
TeSys
Product name
TeSys T
Device short name
LTMR
Product or component type
Motor controller
Device application
Equipment monitoring and control
Measuring current
5…100 A
Rated supply voltage [Us]
24 V DC
Current consumption
56...127 mA
supply voltage limits
20.4…26.24 V DC
Communication port protocol
Modbus TCP / Ethernet / IP
bus type
Ethernet IEEE 802.3 interface Addressing 0...159, Transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs
Complementary
[Ui] rated insulation voltage
690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage
6 kV current or voltage measuring circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
short-circuit resistance
100 kA conforming to EN/IEC 60947-4-1
associated fuse rating
4 A gG for Output
0.5 A gG for control circuit
Protection type
Locked rotor
Overload
Thermal overload protection
Earth leakage protection
Reverse polarity protection
Overload (time)
Power factor variation
Phase imbalance
Load fluctuation
Phase failure
Thermal protection
Network type and machine diagnostics
Fault recording
Trip context information
Waiting time after overload trip
Trip history information
Operating hours / operational time counter
Motor control command recording
Starting current and time
Phase and earth fault odometers
Event recording
Remaining operational time before overload trip
number of logic inputs
6
input current
7 mA
Current state 0 guaranteed
Logic input: < 5 V and <= 15 mA of 5 ms
Current state 1 guaranteed
Logic input: < 15 V and 2...15 mA of 15 ms
maximum output switching frequency
2 Hz
load current
5 A at 250 V AC of logic output
5 A at 30 V DC of logic output
admissible power
480 VA (AC-15), Ie = 2 A, 500000 cycles (Output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (Output)
maximum operating rate
1800 cyc/h
contact type and composition
1 NO + 1 NC fault signal
3 NO
measurement type
Iavg average current
Earth fault current
Temperature
I1 phase current, I2, I3 RMS
Current unbalance
measurement accuracy
5...15 % internal earth fault current measurement
1 % Voltage (100...830 V)
3 % Power factor
5 % external earth fault current measurement
+/- 30 min/year internal clock
0.02 Temperature
5 % active and reactive power
0.02 Current
Overvoltage category
III
Date: 04/17/2024
Weight: 0.460Kg
Measurements: 10X15X24
Locator: A1P2B
Dear customers, if the material is intended for resale, the ST (Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment is exclusively the buyer's.
Cabo Eletro Comercial LTDA thanks you.
5 reasons to be our customer:
![]() |
Exceptional Support - Our friendly support team is available around the clock to help customers with any questions or concerns. We want our products to provide maximum joy and value without complications. That's why we insist on being available to help when |
![]() |
Agile and Affordable Shipping - We have partnerships with the best shipping companies in the country and worldwide. We ship orders all over the world. |
![]() |
Accurate Item Description - As we sell items from different states, we always strive to be as precise as possible in our item descriptions so that the customer knows exactly the quality of the item they are purchasing. |
![]() |
Unbeatable Price - Cabo Eletro's main policy is to have the lowest price in the market. Our product catalog is constantly updated so that our prices are the lowest worldwide. |
![]() |
Easy, Fast, and Secure Ordering - Orders placed in our store are 100% secure as they are processed by the best existing payment tools. |