SCHNEIDER

Schneider Tripolar Breaker NSX100B TM 40D 3P2D 28/40A

Last unit
R$ 650,00 BRL
Last unit in stockOrder now - dispatch within 1 business day.
Code
WS3731
GTIN
3606480006494
Category
Three-pole circuit breaker
Dispatch
Within 1 business day for in-stock items.
1 available in stock
Need an invoice, volume pricing, or special terms? Receive an email quote with this item already included - for individuals, companies, and export buyers.
  • Top seller on Mercado Livre and eBay
  • Business invoicing available
  • Dispatch within 1 business day
  • Secure payment
Payment methods
mastervisaboletopixamerican expressdiners clubapple paygoogle payelo
Technical specifications

Main item details

Brand
SCHNEIDER
SKU / Internal code
WS3731
GTIN
3606480006494
Product type
Three-pole circuit breaker
Condition
Condition shown in specs
Stock
Last unit
Brand
Schneider
Model
NSX100B TM 40D 3P2D LV429544
Thermal trip
This mechanism protects against prolonged overloads. When the electric current exceeds the nominal value for an extended period, the heat generated in the circuit breaker causes a bimetallic strip to bend, activating the trip mechanism and interrupting the electrical circuit.
Magnetic trip
This mechanism responds quickly to current surges, such as those caused by short circuits. When a very high current passes through the circuit breaker, a magnetic field is generated within the device. This magnetic field moves a movable core which, in turn, activates the trip mechanism, immediately interrupting the electrical circuit.
L
for overload protection (thermal)
I
for short-circuit protection (magnetic)
Date
03/19/2024
Weight
1.6 kg
Measurements
10x15x24
Locator
B5P2A
Description

About this item

ABB NSX100B TM 40D 3P2D 28/40A LV429544 Three-Pole Circuit Breaker

New product out of manufacturer's box

Brand: Schneider

Model: NSX100B TM 40D 3P2D LV429544

A thermomagnetic circuit breaker is a protective device used in electrical systems to interrupt the electric current in case of overload or short circuit. It is designed to ensure the safety of electrical installations, equipment, and people operating or near these systems.

Thermal trip: This mechanism protects against prolonged overloads. When the electric current exceeds the nominal value for an extended period, the heat generated in the circuit breaker causes a bimetallic strip to bend, activating the trip mechanism and interrupting the electrical circuit.

Magnetic trip: This mechanism responds quickly to current surges, such as those caused by short circuits. When a very high current passes through the circuit breaker, a magnetic field is generated within the device. This magnetic field moves a movable core which, in turn, activates the trip mechanism, immediately interrupting the electrical circuit.

The combination of these two mechanisms provides effective protection against different types of electrical faults. Thermomagnetic circuit breakers are commonly used in residential, commercial, and industrial electrical systems due to their reliability and ability to protect against a variety of electrical problems.

CIRCUIT BREAKER NSX100B TM40D 3P2D

ComPact NSX100...250

Device Short Name

Product or Component Type

Circuit Breaker

Device Application

Number of poles

Protected Poles Description

[In] Rated Current

[Ue] Rated Operational Voltage

690 V AC 50/60 Hz

Network Frequency

Suitability for Isolation

Yes conforming to EN/IEC 60947-2

Utilization Category

[Icu] rated ultimate short-circuit breaking capacity

15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2

20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2

25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

Performance level

B 25 kA 415 V AC

Trip Unit Technology

Trip Unit Protection Functions

Circuit breaker mounting mode

[Ui] Rated Insulation Voltage

800 V AC 50/60 Hz

[Uimp] Rated Impulse Withstand Voltage

[Ics] rated service short-circuit breaking capacity

20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2

25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

7.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2

Mechanical Durability

Electrical Durability

10000 cycles at 690 V pol

20000 cycles at 690 V pol/2

30000 cycles at 440 V pol

50000 cycles at 440 V pol/2

Mounting Support

Upstream Connections

Downstream Connections

Connection Pitch

Protection Type

L: for overload protection (thermal)

I: for short-circuit protection (magnetic)

Trip Unit Rating

Long-time pick-up adjustment type Ir (thermal protection)

[Ir] long-time protection pick-up adjustment range

Long-time protection delay adjustment type tr

[tr] long-time protection delay adjustment range

120…400 s at 1.5 x pol

Short-time protection pick-up adjustment type Isd

[Isd] Short-time protection pick-up adjustment range

Short-time protection delay adjustment type tsd

Earth Leakage Protection

Date: 03/19/2024

Measurements: 10x15x24

Dear customers, if the material is intended for resale, the ST (Tax Substitution) value may apply.

If the transaction is subject to this tax, the buyer is solely responsible for its payment.

Cabo Eletro Comercial LTDA thanks you.

Why buy here

5 reasons to buy from Cabo Eletro

  1. 01 Proven reputation Top seller on Mercado Livre and eBay, with a public sales history.
  2. 02 Traceability and invoicing Business invoicing and electronic invoices are available for purchases.
  3. 03 Hard-to-find inventory 12,000+ SKUs, including discontinued and replacement items.
  4. 04 Fast dispatch In-stock items ship within 1 business day after confirmation.
  5. 05 Technical support We help validate the code and application before purchase.
List quote

Buying multiple items? Request an email quote

Send this item with other codes or SKUs and receive a consolidated quote with invoice details and volume conditions. We support individual buyers, companies, and international buyers.

R$ 650,00 BRL
WhatsApp
Product Image
Product Image
Product Image
Product Image
Product Image
Schneider Tripolar Breaker NSX100B TM 40D 3P2D 28/40A
R$ 650,00 BRL
In Stock Pre order Out of stock
MarcaSCHNEIDER
Part number / SKUWS3731
GTIN3606480006494
CondiçãoConferir na descrição
Estoque1 em estoque
Garantia e procedênciaInformadas na proposta comercial
EnvioDespacho conforme disponibilidade
Add to Wishlist

mastervisaboletopixamerican expressdiners clubapple paygoogle payelo
SKU: WS3731
Barcode: 3606480006494
Availability : In Stock Pre order Out of stock

Em caso de revenda, entre em contato antecipadamente para consultar valores referentes à Substituição tributária.

Verifique na descrição abaixo o estado do item anunciado. Por lá é indicado se o item é novo, usado e todas as outras informações que o comprador precisa saber antes de realizar a compra.

Descrição

ABB NSX100B TM 40D 3P2D 28/40A LV429544 Three-Pole Circuit Breaker

New product out of manufacturer's box

Brand: Schneider

Model: NSX100B TM 40D 3P2D LV429544

A thermomagnetic circuit breaker is a protective device used in electrical systems to interrupt the electric current in case of overload or short circuit. It is designed to ensure the safety of electrical installations, equipment, and people operating or near these systems.

Thermal trip: This mechanism protects against prolonged overloads. When the electric current exceeds the nominal value for an extended period, the heat generated in the circuit breaker causes a bimetallic strip to bend, activating the trip mechanism and interrupting the electrical circuit.

Magnetic trip: This mechanism responds quickly to current surges, such as those caused by short circuits. When a very high current passes through the circuit breaker, a magnetic field is generated within the device. This magnetic field moves a movable core which, in turn, activates the trip mechanism, immediately interrupting the electrical circuit.

The combination of these two mechanisms provides effective protection against different types of electrical faults. Thermomagnetic circuit breakers are commonly used in residential, commercial, and industrial electrical systems due to their reliability and ability to protect against a variety of electrical problems.

CIRCUIT BREAKER NSX100B TM40D 3P2D

Main

Range

Compact

Product Name

Compact NSX

Product Line

ComPact NSX100...250

Device Short Name

NSX100B

Product or Component Type

Circuit Breaker

Device Application

Distribution

Number of poles

3P

Protected Poles Description

2t

[In] Rated Current

40 A at 40 °C

[Ue] Rated Operational Voltage

690 V AC 50/60 Hz

Network Type

AC

Network Frequency

50/60 Hz

Suitability for Isolation

Yes conforming to EN/IEC 60947-2

Utilization Category

Category A

[Icu] rated ultimate short-circuit breaking capacity

15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2

20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2

25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

Performance level

B 25 kA 415 V AC

Trip Unit Name

TM-D

Trip Unit Technology

Thermomagnetic

Trip Unit Protection Functions

LI

Control Type

Toggle

Circuit breaker mounting mode

Fixed

Complementary

[Ui] Rated Insulation Voltage

800 V AC 50/60 Hz

[Uimp] Rated Impulse Withstand Voltage

8 kV

[Ics] rated service short-circuit breaking capacity

20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2

25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

7.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2

Mechanical Durability

50000 cycles

Electrical Durability

10000 cycles at 690 V pol

20000 cycles at 690 V pol/2

30000 cycles at 440 V pol

50000 cycles at 440 V pol/2

Mounting Support

Backplate

Upstream Connections

Front

Downstream Connections

Front

Connection Pitch

35 mm

Protection Type

L: for overload protection (thermal)

I: for short-circuit protection (magnetic)

Trip Unit Rating

40 A at 40 °C

Long-time pick-up adjustment type Ir (thermal protection)

Adjustable

[Ir] long-time protection pick-up adjustment range

0.7...1 x pol

Long-time protection delay adjustment type tr

Fixed

[tr] long-time protection delay adjustment range

120…400 s at 1.5 x pol

15 s at 6 x Ir

Short-time protection pick-up adjustment type Isd

Fixed

[Isd] Short-time protection pick-up adjustment range

500 A

Short-time protection delay adjustment type tsd

Fixed

Earth Leakage Protection

Without

Date: 03/19/2024

Weight: 1.600

Measurements: 10x15x24

Locator: B5P2A

Dear customers, if the material is intended for resale, the ST (Tax Substitution) value may apply.

If the transaction is subject to this tax, the buyer is solely responsible for its payment.

Cabo Eletro Comercial LTDA thanks you.

5 motivos para comprar conosco

5 reasons to be our customer:

reasons_1

Exceptional Support - Our friendly support team is available around the clock to help customers with any questions or concerns. We want our products to provide maximum joy and value without complications. That's why we insist on being available to help when

reasons_2 Agile and Affordable Shipping - We have partnerships with the best shipping companies in the country and worldwide. We ship orders all over the world.
reasons_4 Accurate Item Description - As we sell items from different states, we always strive to be as precise as possible in our item descriptions so that the customer knows exactly the quality of the item they are purchasing.
reasons_3 Unbeatable Price - Cabo Eletro's main policy is to have the lowest price in the market. Our product catalog is constantly updated so that our prices are the lowest worldwide.
reasons_5 Easy, Fast, and Secure Ordering - Orders placed in our store are 100% secure as they are processed by the best existing payment tools.