



GE Three-Phase Circuit Breaker G63D06 D-Curve 6A 400V 6kA
400 in stock- Code
- 6970
- Category
- Circuit breakers
- Dispatch
- Within 1 business day for in-stock items.
- Top seller on Mercado Livre and eBay
- Business invoicing available
- Dispatch within 1 business day
- Secure payment
Choose the buyer type - we open the form with this product already filled in.
Main item details
- Brand
- GE
- SKU / Internal code
- 6970
- Product type
- Circuit breakers
- Condition
- Condition shown in specs
- Stock
- 400 in stock
- Brand
- GE
- Model
- G63D06
- Triple-pole
- Means that the circuit breaker has three poles, meaning it is capable of interrupting current in all three phases of a three-phase system.
- D-Curve
- Refers to the tripping curve of the circuit breaker in response to short-circuit currents. Circuit breaker curves represent the relationship between the short-circuit current and the tripping time of the circuit breaker. The D-curve is one of the classifications, where the circuit breaker is designed to interrupt higher short-circuit currents than other curve types, such as B or C curves, within a specific time.
- Date
- 06/06/22
- Weight
- 0.1 kg
- Measurements
- 10x10x10
- Locator
- B18P4C
About this item
GE G63D06 D-Curve 6A 400v 6kA Triple-Pole Circuit Breaker
New product out of manufacturer's box
A triple-pole circuit breaker with a D-curve is an electrical protection device used in power distribution systems.
Triple-pole: Means that the circuit breaker has three poles, meaning it is capable of interrupting current in all three phases of a three-phase system.
D-Curve: Refers to the tripping curve of the circuit breaker in response to short-circuit currents. Circuit breaker curves represent the relationship between the short-circuit current and the tripping time of the circuit breaker. The D-curve is one of the classifications, where the circuit breaker is designed to interrupt higher short-circuit currents than other curve types, such as B or C curves, within a specific time.
D-curve circuit breakers are commonly used in circuits that power equipment requiring higher current peaks during startup, such as electric motors, transformers, and systems dealing with inductive loads. They offer robust protection against short-circuit currents and overloads, especially in environments where there is a high power demand.
IEC 60947-2 CAT A 50°C
IN=6A 50/60HZ 14IN
UE=240VAC ICU = 20KA
UE= 415VAC ICU = 10KA
UE= 440VAC ICU= 6KA
ICS= 75% ICU UIMP= 4KV
Weight: 0.100KG
Measurements: 10x10x10
Locator: B18P4C
Cabo Eletro Comercial ltda thanks you
5 reasons to buy from Cabo Eletro
- 01 Proven reputation Top seller on Mercado Livre and eBay, with a public sales history.
- 02 Traceability and invoicing Business invoicing and electronic invoices are available for purchases.
- 03 Hard-to-find inventory 12,000+ SKUs, including discontinued and replacement items.
- 04 Fast dispatch In-stock items ship within 1 business day after confirmation.
- 05 Technical support We help validate the code and application before purchase.
Buying multiple items? Request an email quote
Send this item with other codes or SKUs and receive a consolidated quote with invoice details and volume conditions. We support individual buyers, companies, and international buyers.
Em caso de revenda, entre em contato antecipadamente para consultar valores referentes à Substituição tributária.
Verifique na descrição abaixo o estado do item anunciado. Por lá é indicado se o item é novo, usado e todas as outras informações que o comprador precisa saber antes de realizar a compra.
GE G63D06 D-Curve 6A 400v 6kA Triple-Pole Circuit Breaker
New product out of manufacturer's box
Brand: GE
Model: G63D06
A triple-pole circuit breaker with a D-curve is an electrical protection device used in power distribution systems.
Triple-pole: Means that the circuit breaker has three poles, meaning it is capable of interrupting current in all three phases of a three-phase system.
D-Curve: Refers to the tripping curve of the circuit breaker in response to short-circuit currents. Circuit breaker curves represent the relationship between the short-circuit current and the tripping time of the circuit breaker. The D-curve is one of the classifications, where the circuit breaker is designed to interrupt higher short-circuit currents than other curve types, such as B or C curves, within a specific time.
D-curve circuit breakers are commonly used in circuits that power equipment requiring higher current peaks during startup, such as electric motors, transformers, and systems dealing with inductive loads. They offer robust protection against short-circuit currents and overloads, especially in environments where there is a high power demand.
IEC 60947-2 CAT A 50°C
IN=6A 50/60HZ 14IN
UE=240VAC ICU = 20KA
UE= 415VAC ICU = 10KA
UE= 440VAC ICU= 6KA
ICS= 75% ICU UIMP= 4KV
Date: 06/06/22
Weight: 0.100KG
Measurements: 10x10x10
Locator: B18P4C
Cabo Eletro Comercial ltda thanks you
gp
5 reasons to be our customer:
![]() |
Exceptional Support - Our friendly support team is available around the clock to help customers with any questions or concerns. We want our products to provide maximum joy and value without complications. That's why we insist on being available to help when |
![]() |
Agile and Affordable Shipping - We have partnerships with the best shipping companies in the country and worldwide. We ship orders all over the world. |
![]() |
Accurate Item Description - As we sell items from different states, we always strive to be as precise as possible in our item descriptions so that the customer knows exactly the quality of the item they are purchasing. |
![]() |
Unbeatable Price - Cabo Eletro's main policy is to have the lowest price in the market. Our product catalog is constantly updated so that our prices are the lowest worldwide. |
![]() |
Easy, Fast, and Secure Ordering - Orders placed in our store are 100% secure as they are processed by the best existing payment tools. |





