Motor Starter Telemecanique GV2-P14 6-10A
Last unit- Code
- WS7353
- GTIN
- 7892544313387
- Category
- Motor protector circuit-breaker
- Dispatch
- Within 1 business day for in-stock items.
- Top seller on Mercado Livre and eBay
- Business invoicing available
- Dispatch within 1 business day
- Secure payment
Choose the buyer type - we open the form with this product already filled in.
Main item details
- Brand
- TELEMECANIQUE
- SKU / Internal code
- WS7353
- GTIN
- 7892544313387
- Product type
- Motor protector circuit-breaker
- Condition
- Condition shown in specs
- Stock
- Last unit
- Brand
- Telemecanique
- Model
- GV2-P14
- 35mm DIN rail
- clip-on
- Panel
- screw-mounted (with 2 x M4 screws)
- Date
- 03/12/2024
- Weight
- 0.32 g
- Measurements
- 10x15x24
- Locator
- A13P2B
About this item
Telemecanique GV2-P14 6-10A Motor Circuit Breaker
Used product, out of manufacturer's box
Brand: Telemecanique
A motor circuit breaker is an electrical protection device designed to protect electric motors against common faults such as overload, short-circuit, and phase loss. It combines the functions of a circuit breaker and a thermal relay, ensuring an integrated and efficient solution for motor safety.
Overload Protection (Thermal):
A bimetallic element in the circuit breaker heats up when the motor draws current above its nominal limit for a prolonged period.
This heating causes the element to deform and trigger the circuit shutdown.
Short-Circuit Protection (Magnetic):
A magnetic coil detects abrupt current increases caused by short-circuits.
When the peak is detected, the circuit breaker trips instantly.
Phase Loss Protection:
In three-phase motors, the loss of one phase causes a current imbalance. The circuit breaker detects this fault and shuts down the motor to prevent damage.
A motor circuit breaker is an electrical protection device designed to protect electric motors against common faults such as overload, short-circuit, and phase loss. It combines the functions of a circuit breaker and a thermal relay, ensuring an integrated and efficient solution for motor safety.
Overload Protection (Thermal):
A bimetallic element in the circuit breaker heats up when the motor draws current beyond its nominal limit for a prolonged period.
This heating causes the element to deform and trigger the circuit shutdown.
Short-Circuit Protection (Magnetic):
A magnetic coil detects abrupt current increases caused by short-circuits.
When the peak is detected, the circuit breaker trips instantly.
Phase Loss Protection:
In three-phase motors, the loss of one phase causes a current imbalance. The circuit breaker detects this fault and shuts down the motor to prevent damage.
Current Adjustment:
Allows setting the current limit according to motor specifications.
Automatic Trip:
Protects against faults without the need for immediate manual intervention.
After tripping, it can be manually reclosed to restore operation.
Compatible with Three-Phase and Single-Phase Motors:
Used in systems of different voltages and powers.
Machines with electric motors, such as compressors, pumps, and conveyor belts.
Automation Systems:
Motor protection in automatically controlled systems.
Water pumps and irrigation motors.
Commercial Infrastructures:
Ventilation and air conditioning systems.
Tesys Deca 6-10A thermal-magnetic motor circuit breaker with rotary knob
The new generations of TeSys Deca motor circuit breakers - frame 2 offer a complete solution for almost all applications. It provides short-circuit protection, overload protection, and motor control (ON/OFF). This product has 3 poles, a capacity of 6-10A/690V, and is intended for 3-4kW/400V three-phase motor applications. It provides thermal-magnetic protection with a thermal adjustment range of 6-10A, magnetic trip at 9xIn, and high breaking capacity Icu 100kA@400V. In addition, it features IP20 protection and screw terminal connection. It also allows start/stop control via a rotary knob guaranteed for 100,000 AC-3 cycles. This product is multi-standard certified (IEC, UL, CSA, CCC, EAC, Marine). Tesys Deca motor circuit breakers carry the Green PremiumTM label, which promises compliance with the latest regulations, transparency in environmental impacts, circular, and low CO2 products.
Product or component type
Motor circuit breaker
Device short name
Device application
Motor protection
Tripping unit technology
Thermal-magnetic
Poles description
Utilisation category
Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency
50/60 Hz conforming to IEC 60947-4-1
3 kW at 400/415 V AC 50/60 Hz
5 kW at 500 V AC 50/60 Hz
5.5 kW at 690 V AC 50/60 Hz
Breaking capacity
100 kA Icu at 230/240 V AC 50/60 Hz for IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz for IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz for IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz for IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz for IEC 60947-2
[Ics] rated service short-circuit breaking capacity
100 % at 230/240 V AC 50/60 Hz for IEC 60947-2
100 % at 400/415 V AC 50/60 Hz for IEC 60947-2
100 % at 440 V AC 50/60 Hz for IEC 60947-2
100 % at 500 V AC 50/60 Hz for IEC 60947-2
100 % at 690 V AC 50/60 Hz for IEC 60947-2
[In] rated current
Thermal protection adjustment range
6…10 A conforming to IEC 60947-4-1
Magnetic tripping current
[Ith] conventional free-air thermal current
10 A conforming to IEC 60947-4-1
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-2
Phase failure sensitivity
Yes conforming to IEC 60947-4-1
Suitability for isolation
Yes conforming to IEC 60947-1
Power dissipation per pole
Mechanical durability
Electrical durability
100000 cycles of AC-3 at 415 V pol
100000 cycles of AC-3e at 415 V pol
Continuous conforming to IEC 60947-4-1
Tightening torque
1.7 N.m - on screw connection
35mm DIN rail: clip-on
Panel: screw-mounted (with 2 x M4 screws)
Mounting position
Date: 03/12/2024
Measurements: 10x15x24
Locator: A13P2B
Dear customers, if the material is intended for resale, the ICMS-ST (Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment lies exclusively with the buyer.
Cabo Eletro Comercial LTDA thanks you
5 reasons to buy from Cabo Eletro
- 01 Proven reputation Top seller on Mercado Livre and eBay, with a public sales history.
- 02 Traceability and invoicing Business invoicing and electronic invoices are available for purchases.
- 03 Hard-to-find inventory 12,000+ SKUs, including discontinued and replacement items.
- 04 Fast dispatch In-stock items ship within 1 business day after confirmation.
- 05 Technical support We help validate the code and application before purchase.
Buying multiple items? Request an email quote
Send this item with other codes or SKUs and receive a consolidated quote with invoice details and volume conditions. We support individual buyers, companies, and international buyers.
Em caso de revenda, entre em contato antecipadamente para consultar valores referentes à Substituição tributária.
Verifique na descrição abaixo o estado do item anunciado. Por lá é indicado se o item é novo, usado e todas as outras informações que o comprador precisa saber antes de realizar a compra.
Telemecanique GV2-P14 6-10A Motor Circuit Breaker
Used product, out of manufacturer's box
Brand: Telemecanique
Model: GV2-P14
A motor circuit breaker is an electrical protection device designed to protect electric motors against common faults such as overload, short-circuit, and phase loss. It combines the functions of a circuit breaker and a thermal relay, ensuring an integrated and efficient solution for motor safety.
How it works?
Overload Protection (Thermal):
A bimetallic element in the circuit breaker heats up when the motor draws current above its nominal limit for a prolonged period.
This heating causes the element to deform and trigger the circuit shutdown.
Short-Circuit Protection (Magnetic):
A magnetic coil detects abrupt current increases caused by short-circuits.
When the peak is detected, the circuit breaker trips instantly.
Phase Loss Protection:
In three-phase motors, the loss of one phase causes a current imbalance. The circuit breaker detects this fault and shuts down the motor to prevent damage.
A motor circuit breaker is an electrical protection device designed to protect electric motors against common faults such as overload, short-circuit, and phase loss. It combines the functions of a circuit breaker and a thermal relay, ensuring an integrated and efficient solution for motor safety.
How it works?
Overload Protection (Thermal):
A bimetallic element in the circuit breaker heats up when the motor draws current beyond its nominal limit for a prolonged period.
This heating causes the element to deform and trigger the circuit shutdown.
Short-Circuit Protection (Magnetic):
A magnetic coil detects abrupt current increases caused by short-circuits.
When the peak is detected, the circuit breaker trips instantly.
Phase Loss Protection:
In three-phase motors, the loss of one phase causes a current imbalance. The circuit breaker detects this fault and shuts down the motor to prevent damage.
Main Features:
Current Adjustment:
Allows setting the current limit according to motor specifications.
Automatic Trip:
Protects against faults without the need for immediate manual intervention.
Manual Reset:
After tripping, it can be manually reclosed to restore operation.
Compatible with Three-Phase and Single-Phase Motors:
Used in systems of different voltages and powers.
Applications:
Industries:
Machines with electric motors, such as compressors, pumps, and conveyor belts.
Automation Systems:
Motor protection in automatically controlled systems.
Agribusiness:
Water pumps and irrigation motors.
Commercial Infrastructures:
Ventilation and air conditioning systems.
Tesys Deca 6-10A thermal-magnetic motor circuit breaker with rotary knob
The new generations of TeSys Deca motor circuit breakers - frame 2 offer a complete solution for almost all applications. It provides short-circuit protection, overload protection, and motor control (ON/OFF). This product has 3 poles, a capacity of 6-10A/690V, and is intended for 3-4kW/400V three-phase motor applications. It provides thermal-magnetic protection with a thermal adjustment range of 6-10A, magnetic trip at 9xIn, and high breaking capacity Icu 100kA@400V. In addition, it features IP20 protection and screw terminal connection. It also allows start/stop control via a rotary knob guaranteed for 100,000 AC-3 cycles. This product is multi-standard certified (IEC, UL, CSA, CCC, EAC, Marine). Tesys Deca motor circuit breakers carry the Green PremiumTM label, which promises compliance with the latest regulations, transparency in environmental impacts, circular, and low CO2 products.
Main
range
TeSys Deca
Product name
TeSys GV2
Product or component type
Motor circuit breaker
Device short name
GV2P
Device application
Motor protection
Tripping unit technology
Thermal-magnetic
Complementary
Poles description
3P
Network type
AC
Utilisation category
Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency
50/60 Hz conforming to IEC 60947-4-1
Motor power kW
3 kW at 400/415 V AC 50/60 Hz
5 kW at 500 V AC 50/60 Hz
5.5 kW at 690 V AC 50/60 Hz
Breaking capacity
100 kA Icu at 230/240 V AC 50/60 Hz for IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz for IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz for IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz for IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz for IEC 60947-2
[Ics] rated service short-circuit breaking capacity
100 % at 230/240 V AC 50/60 Hz for IEC 60947-2
100 % at 400/415 V AC 50/60 Hz for IEC 60947-2
100 % at 440 V AC 50/60 Hz for IEC 60947-2
100 % at 500 V AC 50/60 Hz for IEC 60947-2
100 % at 690 V AC 50/60 Hz for IEC 60947-2
Control type
Rotary handle
[In] rated current
10 A
Thermal protection adjustment range
6…10 A conforming to IEC 60947-4-1
Magnetic tripping current
149 A
[Ith] conventional free-air thermal current
10 A conforming to IEC 60947-4-1
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-2
Phase failure sensitivity
Yes conforming to IEC 60947-4-1
Suitability for isolation
Yes conforming to IEC 60947-1
Power dissipation per pole
2.5 W
Mechanical durability
100000 cycles
Electrical durability
100000 cycles of AC-3 at 415 V pol
100000 cycles of AC-3e at 415 V pol
Rated duty
Continuous conforming to IEC 60947-4-1
Tightening torque
1.7 N.m - on screw connection
Mounting mode
35mm DIN rail: clip-on
Panel: screw-mounted (with 2 x M4 screws)
Mounting position
Horizontal
Vertical
Date: 03/12/2024
Weight: 0.320g
Measurements: 10x15x24
Locator: A13P2B
Dear customers, if the material is intended for resale, the ICMS-ST (Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment lies exclusively with the buyer.
Cabo Eletro Comercial LTDA thanks you
5 reasons to be our customer:
![]() |
Exceptional Support - Our friendly support team is available around the clock to help customers with any questions or concerns. We want our products to provide maximum joy and value without complications. That's why we insist on being available to help when |
![]() |
Agile and Affordable Shipping - We have partnerships with the best shipping companies in the country and worldwide. We ship orders all over the world. |
![]() |
Accurate Item Description - As we sell items from different states, we always strive to be as precise as possible in our item descriptions so that the customer knows exactly the quality of the item they are purchasing. |
![]() |
Unbeatable Price - Cabo Eletro's main policy is to have the lowest price in the market. Our product catalog is constantly updated so that our prices are the lowest worldwide. |
![]() |
Easy, Fast, and Secure Ordering - Orders placed in our store are 100% secure as they are processed by the best existing payment tools. |