




ABB Motor Circuit Breaker MO165-20 1SAM4610000R1012 20A 690v 8kV
10 in stock- Code
- 7353
- GTIN
- 4013614486135
- Category
- Circuit breakers
- Dispatch
- Within 1 business day for in-stock items.
- Top seller on Mercado Livre and eBay
- Business invoicing available
- Dispatch within 1 business day
- Secure payment
Choose the buyer type - we open the form with this product already filled in.
Main item details
- Brand
- ABB
- SKU / Internal code
- 7353
- GTIN
- 4013614486135
- Product type
- Circuit breakers
- Condition
- Condition shown in specs
- Stock
- 10 in stock
- Faixa de ajuste
- Nenhum
- Tensão operacional nominal
- Circuito Principal 690 V AC
- Frequência Nominal (f)
- Circuito Principal 50 Hz
- Perda de energia
- 3,72 W.
- Número de postes
- 3
- Grau de proteção
- Alojamento IP20
- Grau de poluição
- 3
- Durabilidade Elétrica
- 25.000 ciclos
- Durabilidade Mecânica
- 50.000 ciclos
- Tipo de terminal
- Terminais de parafuso
- Torque de aperto
- Circuito Principal 4 N·m
- Chave de fenda recomendada
- Pozidriv 2
About this item
ABB Motor Protection Circuit Breaker MO165-20 1SAM4610000R1012 20A 690v 8kV
New product in manufacturer's box
Model: MO165-20 1SAM4610000R1012
The MO165 magnetic-only manual motor starter is a compact and powerful line for motor protection up to 45 kW (400 V) with a width of 55 mm. The devices are used to manually switch loads/motors on and off and protect them reliably and without the need for a fuse against short circuits. The manual motor starter offers a rated service short-circuit breaking capacity of up to 100 kA at 400 V AC. A combination with overload relays or motor controllers allows the protection of motors. Other features are the built-in disconnection function, trip-free mechanism and a rotary handle with a clear indication of the switch position. Magnetic-only manual motor starters are suitable for three-phase and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt releases.
Rated Service Short-Circuit Breaking Capacity (I cs ):(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 100 kA
(440 V AC) 75 kA
(500 V AC) 40 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (I cu ):(230 V AC) 100 kA
(250 V DC) 100 kA
(400 V AC) 100 kA
(440 V AC) 75 kA
(500 V AC) 40 kA
(690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (I i ):300A
Adjustment Range:None
Rated Operational Power AC-3 (P e ):(400 V) Three-phase 7.5 kW
Rated Operational Power AC-3e (P e ):(400 V) Three-phase 7.5 kW
Rated Operational Voltage:Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (I e ):20A
Rated Operational Current AC-3 (I e ):20A
Rated Operational Current AC-3e (I e ):20A
Rated Operational Current DC-5 (I e ):20A
Rated Frequency (f):Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (U imp ):Main Circuit 8 kV
Rated Insulation Voltage (U i ):1000 V
Power Loss:3.72 W.
Number of Poles:3
Conventional Free-air Thermal Current (I th ):Main Circuit 20 A
Degree of Protection:Housing IP20
Main Circuit Terminals IP10
Pollution Degree:3
Electrical Durability:25,000 cycles
Mechanical Durability:50,000 cycles
Terminal Type:Screw Terminals
Main Circuit Connection Capacity:Flexible with ferrule 1/2x 1 ... 35 mm²
Flexible with insulated ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening Torque:Main Circuit 4 N·m
Wire Stripping Length:Main Circuit 16 mm
Recommended Screwdriver:Pozidriv 2
Mounting Position:1 ... 6
DIN Rail Mounting:TH35-15 (35 x 15 mm mounting rail) according to IEC 60715
TH35-7,5 (35 x 7.5 mm mounting rail) according to IEC 60715
Minimum Mounting Distance:Electrical conducting plate, horizontal - up to 1000 V 1.5 mm
Electrical conducting plate, horizontal - up to 400 V 0 mm
Electrical conducting plate, horizontal - up to 690 V 1.5 mm
Electrical conducting plate, vertical 75 mm
Other device Same type, horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:Rotary Handle
Contact Position Indication:ON / OFF / TRIP
Standards:CSA 22.2 No. 14
60947-2 IEC/EN 60947-4-1
Remarks:For motor overload protection, an appropriate thermal or electronic overload relay must be used
UL/CSA Technical
Short-Circuit Current Rating (SCCR):Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuse or Breaker, Group Installations (480 V AC) 65 kA
Any UL Listed Fuse or Breaker, Group Installations (600 V AC) 30 kA
Any UL Listed Fuse or Breaker, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuse or Circuit -Breaker, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuse or Breaker, Branch Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuse or Breaker, Branch Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
UL/CSA Maximum Operating Voltage:Main Circuit 600 V AC
UL/CSA Amperage:20A
UL/CSA Power Rating:(200 V AC) Three-phase 5 Hp
(208 V AC) Three-phase 5 Hp
(220 ... 240 V AC) Three-phase 5 Hp
(440 ... 480 V AC) Three-phase 10 Hp
(550 ... 600 V AC) V AC) Three-phase 15 HP
Full Load Amps Motor Use:(200 V AC) Three-phase 17.5 A
(208 V AC) Three-phase 16.7 A
(220 ... 240 V AC) Three-phase 15.2 A
(440 ... 480 V AC) Three-phase 14 A
(550 ... 600 V AC) V AC) Three-phase 17 A
Locked Rotor Amps:(200 V AC) Three-phase 105.8 A
(208 V AC) Three-phase 102 A
(220 ... 240 V AC) Three-phase 92 A
(440 ... 480 V AC) Three-phase 81 A
(550 ... 600 V AC) V AC) Three-phase 93 A
UL/CSA General Use Rating:(600 V AC) 20 A
UL/CSA Main Circuit Connection Capacity:Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
UL/CSA Tightening Torque:Main Circuit 35 in·lb
Ambient Temperature:Operation -25 ... +60 °C
Compensated Operation -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:No
Maximum Permissible Operating Altitude:2,000 m
Shock Resistance acc. to IEC 60068-2-27:11 ms Pulse 25g
Vibration Resistance acc. to IEC 60068-2-6:5g / 3 ... 150 Hz
Date 08/07/2022
Measurements 6x14x18
Locator: GP04CL16P06
Cabo Eletro Comercial ltda thanks you
5 reasons to buy from Cabo Eletro
- 01 Proven reputation Top seller on Mercado Livre and eBay, with a public sales history.
- 02 Traceability and invoicing Business invoicing and electronic invoices are available for purchases.
- 03 Hard-to-find inventory 12,000+ SKUs, including discontinued and replacement items.
- 04 Fast dispatch In-stock items ship within 1 business day after confirmation.
- 05 Technical support We help validate the code and application before purchase.
Buying multiple items? Request an email quote
Send this item with other codes or SKUs and receive a consolidated quote with invoice details and volume conditions. We support individual buyers, companies, and international buyers.
Em caso de revenda, entre em contato antecipadamente para consultar valores referentes à Substituição tributária.
Verifique na descrição abaixo o estado do item anunciado. Por lá é indicado se o item é novo, usado e todas as outras informações que o comprador precisa saber antes de realizar a compra.
ABB Motor Protection Circuit Breaker MO165-20 1SAM4610000R1012 20A 690v 8kV
New product in manufacturer's box
Brand: ABB
Model: MO165-20 1SAM4610000R1012
The MO165 magnetic-only manual motor starter is a compact and powerful line for motor protection up to 45 kW (400 V) with a width of 55 mm. The devices are used to manually switch loads/motors on and off and protect them reliably and without the need for a fuse against short circuits. The manual motor starter offers a rated service short-circuit breaking capacity of up to 100 kA at 400 V AC. A combination with overload relays or motor controllers allows the protection of motors. Other features are the built-in disconnection function, trip-free mechanism and a rotary handle with a clear indication of the switch position. Magnetic-only manual motor starters are suitable for three-phase and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt releases.
Technical
Rated Service Short-Circuit Breaking Capacity (I cs ):(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 100 kA
(440 V AC) 75 kA
(500 V AC) 40 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (I cu ):(230 V AC) 100 kA
(250 V DC) 100 kA
(400 V AC) 100 kA
(440 V AC) 75 kA
(500 V AC) 40 kA
(690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (I i ):300A
Adjustment Range:None
Rated Operational Power AC-3 (P e ):(400 V) Three-phase 7.5 kW
Rated Operational Power AC-3e (P e ):(400 V) Three-phase 7.5 kW
Rated Operational Voltage:Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (I e ):20A
Rated Operational Current AC-3 (I e ):20A
Rated Operational Current AC-3e (I e ):20A
Rated Operational Current DC-5 (I e ):20A
Rated Frequency (f):Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (U imp ):Main Circuit 8 kV
Rated Insulation Voltage (U i ):1000 V
Power Loss:3.72 W.
Number of Poles:3
Conventional Free-air Thermal Current (I th ):Main Circuit 20 A
Degree of Protection:Housing IP20
Main Circuit Terminals IP10
Pollution Degree:3
Electrical Durability:25,000 cycles
Mechanical Durability:50,000 cycles
Terminal Type:Screw Terminals
Main Circuit Connection Capacity:Flexible with ferrule 1/2x 1 ... 35 mm²
Flexible with insulated ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening Torque:Main Circuit 4 N·m
Wire Stripping Length:Main Circuit 16 mm
Recommended Screwdriver:Pozidriv 2
Mounting Position:1 ... 6
DIN Rail Mounting:TH35-15 (35 x 15 mm mounting rail) according to IEC 60715
TH35-7,5 (35 x 7.5 mm mounting rail) according to IEC 60715
Minimum Mounting Distance:Electrical conducting plate, horizontal - up to 1000 V 1.5 mm
Electrical conducting plate, horizontal - up to 400 V 0 mm
Electrical conducting plate, horizontal - up to 690 V 1.5 mm
Electrical conducting plate, vertical 75 mm
Other device Same type, horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:Rotary Handle
Contact Position Indication:ON / OFF / TRIP
Standards:CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN
60947-2 IEC/EN 60947-4-1
UL 60947-4-1
Remarks:For motor overload protection, an appropriate thermal or electronic overload relay must be used
UL/CSA Technical
Short-Circuit Current Rating (SCCR):Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuse or Breaker, Group Installations (480 V AC) 65 kA
Any UL Listed Fuse or Breaker, Group Installations (600 V AC) 30 kA
Any UL Listed Fuse or Breaker, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuse or Circuit -Breaker, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuse or Breaker, Branch Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuse or Breaker, Branch Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
UL/CSA Maximum Operating Voltage:Main Circuit 600 V AC
UL/CSA Amperage:20A
UL/CSA Power Rating:(200 V AC) Three-phase 5 Hp
(208 V AC) Three-phase 5 Hp
(220 ... 240 V AC) Three-phase 5 Hp
(440 ... 480 V AC) Three-phase 10 Hp
(550 ... 600 V AC) V AC) Three-phase 15 HP
Full Load Amps Motor Use:(200 V AC) Three-phase 17.5 A
(208 V AC) Three-phase 16.7 A
(220 ... 240 V AC) Three-phase 15.2 A
(440 ... 480 V AC) Three-phase 14 A
(550 ... 600 V AC) V AC) Three-phase 17 A
Locked Rotor Amps:(200 V AC) Three-phase 105.8 A
(208 V AC) Three-phase 102 A
(220 ... 240 V AC) Three-phase 92 A
(440 ... 480 V AC) Three-phase 81 A
(550 ... 600 V AC) V AC) Three-phase 93 A
UL/CSA General Use Rating:(600 V AC) 20 A
UL/CSA Main Circuit Connection Capacity:Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
UL/CSA Tightening Torque:Main Circuit 35 in·lb
Environmental
Ambient Temperature:Operation -25 ... +60 °C
Compensated Operation -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:No
Maximum Permissible Operating Altitude:2,000 m
Shock Resistance acc. to IEC 60068-2-27:11 ms Pulse 25g
Vibration Resistance acc. to IEC 60068-2-6:5g / 3 ... 150 Hz
Date 08/07/2022
Weight: 1.050
Measurements 6x14x18
Locator: GP04CL16P06
Cabo Eletro Comercial ltda thanks you
IH
5 reasons to be our customer:
![]() |
Exceptional Support - Our friendly support team is available around the clock to help customers with any questions or concerns. We want our products to provide maximum joy and value without complications. That's why we insist on being available to help when |
![]() |
Agile and Affordable Shipping - We have partnerships with the best shipping companies in the country and worldwide. We ship orders all over the world. |
![]() |
Accurate Item Description - As we sell items from different states, we always strive to be as precise as possible in our item descriptions so that the customer knows exactly the quality of the item they are purchasing. |
![]() |
Unbeatable Price - Cabo Eletro's main policy is to have the lowest price in the market. Our product catalog is constantly updated so that our prices are the lowest worldwide. |
![]() |
Easy, Fast, and Secure Ordering - Orders placed in our store are 100% secure as they are processed by the best existing payment tools. |





