ABB

ABB Contactor AX65-30-11-85 380-400V 50Hz 400-415V 60Hz 115A

11 in stock
R$ 700,00 BRL
In stock - ready to shipShips within 1 business day after confirmation.
Code
7565
GTIN
3471522406859
Category
Automation control components
Dispatch
Within 1 business day for in-stock items.
11 available in stock
Need volume pricing or special terms? Receive an email quote with this item already included - for individuals, companies, and export buyers.
  • Top seller on Mercado Livre and eBay
  • Business invoicing available
  • Dispatch within 1 business day
  • Secure payment
Payment methods
mastervisaboletopixamerican expressdiners clubapple paygoogle payelo
Technical specifications

Main item details

Brand
ABB
SKU / Internal code
7565
GTIN
3471522406859
Product type
Automation control components
Condition
Condition shown in specs
Stock
11 in stock
Descrição do catálogo
Contator AX65-30-11-85 380-400V50Hz/400V-415V60Hz
Tensão operacional nominal
Circuito Auxiliar 690 V
Frequência Nominal (f)
Circuito Auxiliar 50/60 Hz
Capacidade máxima de ruptura
cos phi=0,45 (cos phi=0,35 para Ie > 100 A) a 440 V 1300 A
Tempo de operação
Entre Desenergização da Bobina e Fechamento do Contato NF 7 ... 14 ms
Grau de proteção
seg. conforme IEC 60529, IEC 60947-1, EN 60529 Terminais de bobina IP20
Tipo de terminal
Terminais de parafuso
Torque de Aperto UL/CSA
Circuito Auxiliar 9 pol·lb
Temperatura ambiente
Próximo ao contator equipado com relé térmico O/L -25 ... 55 °C
Resistência Climática
seg. para IEC 60068-2-30 e 60068-2-11 - UTE C 63-100 especificação II
Weight
1,17 kg
Description

About this item

Technical description Overview, applications, and benefits

ABB Contactor AX65-30-11-85 380-400v50Hz 400-415v60Hz 115A

New product in manufacturer's box

Model: AX65-30-11-85 1SBL371074R8511

Catalog description: Contactor AX65-30-11-85 380-400V50Hz/400V-415V60Hz

Long description: AX50...AX80 contactors are mainly used for controlling three-phase motors and power circuits up to 690 V AC. These contactors are of the block type with: – 3 main poles – control circuit: AC operated – additional auxiliary contact blocks (optional) for side mounting and a wide range of accessories.

Number of Main Contacts NO: 3

Number of Main Contacts NC: 0

Number of Auxiliary Contacts NO: 1

Number of Auxiliary Contacts NC: 1

Rated Operational Voltage: Auxiliary Circuit 690 V

Main Circuit 690 V

Rated Frequency (f): Auxiliary Circuit 50/60 Hz

Main Circuit 50/60 Hz

Conventional Free-Air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A

Rated Operational Current AC-1 (I e ): (220 / 240 V) 55 °C 95 A

(690 V) 40 °C 115 A

(690 V) 70 °C 80 A

Rated Operational Current AC-3 (I e ): (415 V) 55 °C 65 A

(440 V) 55 °C 65 A

(500 V) 55 °C 55 A

(690 V) 55 °C 43 A

(380 / 400 V) 55 °C 65 A

(220 / 230 / 240 V) 55 °C 65 A

Rated Operational Power AC-3 (P e ): (415 V) 37 kW

(380 / 400 V) 30 kW

(220 / 230 / 240 V) 18.5 kW

Rated Short-time Withstand Current (I cw ): at 40 °C Ambient Temperature, in Free Air, from a Cold State 10 s 650 A

at 40 °C Ambient Temperature, in Free Air, from a Cold State 15 min 135 A

at 40 °C Ambient Temperature, in Free Air, from a Cold State 1 min 250 A

at 40 °C Ambient Temperature, in Free Air, from a Cold State 1 s 1000 A

at 40 °C Ambient Temperature, in Free Air, from a Cold State 30 s 370 A

for 1 s -empty - A

Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A

Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour

(AC-3) 600 cycles per hour

Rated Insulation Voltage (U i ): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V

Rated Impulse Withstand Voltage (U imp ): Auxiliary Circuit 6 kV

Maximum Mechanical Switching Frequency: 3600 cycles per hour

Rated Control Circuit Voltage (U c ): 50 Hz 380 ... 400 V

60 Hz 400 ... 415 V

Operating Time: Between Coil De-energization and NC Contact Opening 7 ... 14 ms

Between Coil De-energization and NO Contact Closing 4 ... 11 ms

Between Coil Energization and NC Contact Opening 7 ... 22 ms

Between Coil Energization and NO Contact Closing 8 ... 27 ms

Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10

Terminal Type: Screw Terminals

Technical UL/CSA

UL/CSA General Use Rating: (600 V AC) 90 A

UL/CSA Power Rating: (120 V AC) Single Phase 5 hp

(200 ... 208 V AC) Three Phase 20 hp

(220 ... 240 V AC) Three Phase 25 hp

(240 V AC) Single Phase 10 hp

(440 ... 480 V AC) Three Phase 60 hp

(550 ... 600 V AC) Three Phase 75 hp

UL/CSA Tightening Torque: Auxiliary Circuit 9 in·lb

Control Circuit 9 in·lb

Main Circuit 35 in·lb

Ambient Temperature: Near Contactor fitted with O/L Thermal Relay -25 ... 55 °C

Near Contactor without O/L Thermal Relay -40 ... 70 °C

Near Contactor for Storage -60 ... +80 °C

Near Contactor for Operation in Free Air -40 ... 70 °C

Climatic Resistance: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II

Maximum Permissible Operating Altitude: 3000 m

Date 20/07/2022

Measurements 10x14x15

Locator: SL06CL62P4

Cabo Eletro Comercial ltda thanks you

Need to confirm a spec or equivalent? Talk to our technical team
Why buy here

5 reasons to buy from Cabo Eletro

  1. 01 Proven reputation Top seller on Mercado Livre and eBay, with a public sales history.
  2. 02 Traceability and invoicing Business invoicing and electronic invoices are available for purchases.
  3. 03 Hard-to-find inventory 12,000+ SKUs, including discontinued and replacement items.
  4. 04 Fast dispatch In-stock items ship within 1 business day after confirmation.
  5. 05 Technical support We help validate the code and application before purchase.
List quote

Buying multiple items? Request an email quote

Send this item with other codes or SKUs and receive a consolidated quote with invoice details and volume conditions. We support individual buyers, companies, and international buyers.

R$ 700,00 BRL
WhatsApp
Contator ABB AX65-30-11-85 380-400v50Hz 400-415v60Hz 115A - Cabo Eletro
Contator ABB AX65-30-11-85 380-400v50Hz 400-415v60Hz 115A - Cabo Eletro
Contator ABB AX65-30-11-85 380-400v50Hz 400-415v60Hz 115A - Cabo Eletro
Contator ABB AX65-30-11-85 380-400v50Hz 400-415v60Hz 115A - Cabo Eletro
Contator ABB AX65-30-11-85 380-400v50Hz 400-415v60Hz 115A - Cabo Eletro
Contator ABB AX65-30-11-85 380-400v50Hz 400-415v60Hz 115A - Cabo Eletro
ABB Contactor AX65-30-11-85 380-400V 50Hz 400-415V 60Hz 115A
R$ 700,00 BRL
In Stock Pre order Out of stock
MarcaABB
Part number / SKU7565
GTIN3471522406859
CondiçãoConferir na descrição
Estoque11 em estoque
Garantia e procedênciaInformadas na proposta comercial
EnvioDespacho conforme disponibilidade
Add to Wishlist

mastervisaboletopixamerican expressdiners clubapple paygoogle payelo
SKU: 7565
Barcode: 3471522406859
Availability : In Stock Pre order Out of stock

Em caso de revenda, entre em contato antecipadamente para consultar valores referentes à Substituição tributária.

Verifique na descrição abaixo o estado do item anunciado. Por lá é indicado se o item é novo, usado e todas as outras informações que o comprador precisa saber antes de realizar a compra.

Descrição

ABB Contactor AX65-30-11-85 380-400v50Hz 400-415v60Hz 115A

New product in manufacturer's box

Brand: ABB

Model: AX65-30-11-85 1SBL371074R8511

 

Catalog description: Contactor AX65-30-11-85 380-400V50Hz/400V-415V60Hz

Long description: AX50...AX80 contactors are mainly used for controlling three-phase motors and power circuits up to 690 V AC. These contactors are of the block type with: – 3 main poles – control circuit: AC operated – additional auxiliary contact blocks (optional) for side mounting and a wide range of accessories.

 

 

Technical

Number of Main Contacts NO: 3

Number of Main Contacts NC: 0

Number of Auxiliary Contacts NO: 1

Number of Auxiliary Contacts NC: 1

Rated Operational Voltage: Auxiliary Circuit 690 V

Main Circuit 690 V

Rated Frequency (f): Auxiliary Circuit 50/60 Hz

Main Circuit 50/60 Hz

Conventional Free-Air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A

Rated Operational Current AC-1 (I e ): (220 / 240 V) 55 °C 95 A

(690 V) 40 °C 115 A

(690 V) 70 °C 80 A

Rated Operational Current AC-3 (I e ): (415 V) 55 °C 65 A

(440 V) 55 °C 65 A

(500 V) 55 °C 55 A

(690 V) 55 °C 43 A

(380 / 400 V) 55 °C 65 A

(220 / 230 / 240 V) 55 °C 65 A

Rated Operational Power AC-3 (P e ): (415 V) 37 kW

(440 V) 37 kW

(500 V) 37 kW

(690 V) 37 kW

(380 / 400 V) 30 kW

(220 / 230 / 240 V) 18.5 kW

Rated Short-time Withstand Current (I cw ): at 40 °C Ambient Temperature, in Free Air, from a Cold State 10 s 650 A

at 40 °C Ambient Temperature, in Free Air, from a Cold State 15 min 135 A

at 40 °C Ambient Temperature, in Free Air, from a Cold State 1 min 250 A

at 40 °C Ambient Temperature, in Free Air, from a Cold State 1 s 1000 A

at 40 °C Ambient Temperature, in Free Air, from a Cold State 30 s 370 A

for 1 s -empty - A

Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A

Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour

(AC-3) 600 cycles per hour

Rated Insulation Voltage (U i ): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V

Rated Impulse Withstand Voltage (U imp ): Auxiliary Circuit 6 kV

Maximum Mechanical Switching Frequency: 3600 cycles per hour

Rated Control Circuit Voltage (U c ): 50 Hz 380 ... 400 V

60 Hz 400 ... 415 V

Operating Time: Between Coil De-energization and NC Contact Opening 7 ... 14 ms

Between Coil De-energization and NO Contact Closing 4 ... 11 ms

Between Coil Energization and NC Contact Opening 7 ... 22 ms

Between Coil Energization and NO Contact Closing 8 ... 27 ms

Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10

IP10

Terminal Type: Screw Terminals

Technical UL/CSA

UL/CSA General Use Rating: (600 V AC) 90 A

UL/CSA Power Rating: (120 V AC) Single Phase 5 hp

(200 ... 208 V AC) Three Phase 20 hp

(220 ... 240 V AC) Three Phase 25 hp

(240 V AC) Single Phase 10 hp

(440 ... 480 V AC) Three Phase 60 hp

(550 ... 600 V AC) Three Phase 75 hp

UL/CSA Tightening Torque: Auxiliary Circuit 9 in·lb

Control Circuit 9 in·lb

Main Circuit 35 in·lb

Environmental

Ambient Temperature: Near Contactor fitted with O/L Thermal Relay -25 ... 55 °C

Near Contactor without O/L Thermal Relay -40 ... 70 °C

Near Contactor for Storage -60 ... +80 °C

Near Contactor for Operation in Free Air -40 ... 70 °C

Climatic Resistance: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II

Maximum Permissible Operating Altitude: 3000 m

 

 

 

Date 20/07/2022

Weight: 1.170

Measurements 10x14x15

Locator: SL06CL62P4

Cabo Eletro Comercial ltda thanks you

IH

 

5 motivos para comprar conosco

5 reasons to be our customer:

reasons_1

Exceptional Support - Our friendly support team is available around the clock to help customers with any questions or concerns. We want our products to provide maximum joy and value without complications. That's why we insist on being available to help when

reasons_2 Agile and Affordable Shipping - We have partnerships with the best shipping companies in the country and worldwide. We ship orders all over the world.
reasons_4 Accurate Item Description - As we sell items from different states, we always strive to be as precise as possible in our item descriptions so that the customer knows exactly the quality of the item they are purchasing.
reasons_3 Unbeatable Price - Cabo Eletro's main policy is to have the lowest price in the market. Our product catalog is constantly updated so that our prices are the lowest worldwide.
reasons_5 Easy, Fast, and Secure Ordering - Orders placed in our store are 100% secure as they are processed by the best existing payment tools.