{"product_id":"contator-auxiliar-schneider-cad32gd-10a-125vdc-3na-2nf","title":"Schneider Auxiliary Contactor CAD32GD 10A 125VDC 3NO+2NC","description":"\u003cp\u003eSchneider CAD32GD Auxiliary Contactor 10A 125V\u003c\/p\u003e\n\u003cp\u003eUSED product out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: Schneider\u003c\/p\u003e\n\u003cp\u003eModel: CAD32GD 10A 125V\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAn auxiliary contactor is a type of electrical device that is used in conjunction with a main contactor to provide additional control and monitoring functions in electrical systems. It is connected to the main contactor and assists in the process of switching electrical circuits.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThey ensure that certain operations occur in a specific sequence.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAuxiliary contacts can be used to indicate whether a device is on or off.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAuxiliary contacts are mounted in the same enclosure as the main contactor and are operated by it. They are connected to the main contactor's control circuit and can be normally open (NO) or normally closed (NC), depending on the specific application. These devices are commonly found in industrial automation systems, such as machine and process control panels.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTESYS D AUXILIARY CONTACTOR 3NO+2NC 120VDC CAD32GD\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTeSys Deca auxiliary contactor, 5 contacts (3NO + 2NC), 10A\/690V, for controlling AC-15\/DC-13 electromagnetic loads. Provides a 125V DC control circuit with no inrush consumption and equipped with a surge suppression device, screw clamp terminal connection. For high operating rates up to 180 cycles\/min and ambient temperature -40\/+60°C, it achieves high reliability and durability. Compact (45mm width), for mounting on 35mm DIN rail or screw fixing. Multi-standard certification (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS\/REACh).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003eline\u003c\/p\u003e\n\u003cp\u003eTeSys\u003c\/p\u003e\n\u003cp\u003eTeSys Deca\u003c\/p\u003e\n\u003cp\u003eProduct name\u003c\/p\u003e\n\u003cp\u003eTeSys CAD\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eControl relay\u003c\/p\u003e\n\u003cp\u003eDevice short name\u003c\/p\u003e\n\u003cp\u003eCAD\u003c\/p\u003e\n\u003cp\u003econtactor application\u003c\/p\u003e\n\u003cp\u003eControl circuit\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003eUsage category\u003c\/p\u003e\n\u003cp\u003eDC-13\u003c\/p\u003e\n\u003cp\u003eAC-14\u003c\/p\u003e\n\u003cp\u003eAC-15\u003c\/p\u003e\n\u003cp\u003epole contact composition\u003c\/p\u003e\n\u003cp\u003e3 NO + 2 NC\u003c\/p\u003e\n\u003cp\u003e[Ue] rated operational voltage\u003c\/p\u003e\n\u003cp\u003e\u0026lt;= 690 V AC 25...400 Hz\u003c\/p\u003e\n\u003cp\u003econtrol circuit type\u003c\/p\u003e\n\u003cp\u003eStandard DC\u003c\/p\u003e\n\u003cp\u003econtrol circuit voltage\u003c\/p\u003e\n\u003cp\u003e125 V DC\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e6 kV conforming to IEC 60947\u003c\/p\u003e\n\u003cp\u003e[Ith] conventional free air thermal current\u003c\/p\u003e\n\u003cp\u003e10 A (at 60 °C)\u003c\/p\u003e\n\u003cp\u003erated breaking capacity Irms\u003c\/p\u003e\n\u003cp\u003e140 A AC for IEC 60947-5-1\u003c\/p\u003e\n\u003cp\u003e250 A DC for IEC 60947-5-1\u003c\/p\u003e\n\u003cp\u003e[Icw] rated short-time withstand current\u003c\/p\u003e\n\u003cp\u003e100 A - 1 s\u003c\/p\u003e\n\u003cp\u003e120 A - 500 ms\u003c\/p\u003e\n\u003cp\u003e140 A - 100 ms\u003c\/p\u003e\n\u003cp\u003eassociated fuse rating\u003c\/p\u003e\n\u003cp\u003e10 A gG conforming to IEC 60947-5-1\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e600 V UL certified\u003c\/p\u003e\n\u003cp\u003e600 V CSA certified\u003c\/p\u003e\n\u003cp\u003e690 V for IEC 60947-5-1\u003c\/p\u003e\n\u003cp\u003eMounting support\u003c\/p\u003e\n\u003cp\u003eRail\u003c\/p\u003e\n\u003cp\u003ePlate\u003c\/p\u003e\n\u003cp\u003econnections - terminals\u003c\/p\u003e\n\u003cp\u003eScrew terminals 1 cable(s)1…4 mm²Flexible Without cable end\u003c\/p\u003e\n\u003cp\u003eScrew terminals 2 cable(s)1…4 mm²Flexible Without cable end\u003c\/p\u003e\n\u003cp\u003eScrew terminals 1 cable(s)1…4 mm²Flexible With cable end\u003c\/p\u003e\n\u003cp\u003eScrew terminals 2 cable(s)1…2.5 mm²Flexible With cable end\u003c\/p\u003e\n\u003cp\u003eScrew terminals 1 cable(s)1…4 mm²Solid Without cable end\u003c\/p\u003e\n\u003cp\u003eScrew terminals 2 cable(s)1…4 mm²Solid Without cable end\u003c\/p\u003e\n\u003cp\u003etightening torque\u003c\/p\u003e\n\u003cp\u003e1.2 N.m - connect Screw terminals - with Philips screwdriver Nº 2\u003c\/p\u003e\n\u003cp\u003e1.2 N.m - connect Screw terminals - with flat screwdriver of O 6 mm\u003c\/p\u003e\n\u003cp\u003e1.2 N.m - connect Screw terminals - with Pozidriv screwdriver n 2\u003c\/p\u003e\n\u003cp\u003econtrol circuit voltage limits\u003c\/p\u003e\n\u003cp\u003e0.1...0.25 Uc -40…70 °C DC output\u003c\/p\u003e\n\u003cp\u003e0.7...1.25 Uc -40…60 °C DC operation\u003c\/p\u003e\n\u003cp\u003e1...1.25 Uc 60…70 °C DC operation\u003c\/p\u003e\n\u003cp\u003eoperating time\u003c\/p\u003e\n\u003cp\u003e53...72 ms coil energization and NO closing\u003c\/p\u003e\n\u003cp\u003e16...24 ms coil de-energization and NO opening\u003c\/p\u003e\n\u003cp\u003e47...63 ms coil energization and NC opening\u003c\/p\u003e\n\u003cp\u003e15...25 ms coil de-energization and NC closing\u003c\/p\u003e\n\u003cp\u003emechanical durability\u003c\/p\u003e\n\u003cp\u003e30 Mcycles\u003c\/p\u003e\n\u003cp\u003eMaximum operating rate\u003c\/p\u003e\n\u003cp\u003e180 cyc\/min\u003c\/p\u003e\n\u003cp\u003etime constant\u003c\/p\u003e\n\u003cp\u003e28 ms\u003c\/p\u003e\n\u003cp\u003einrush power in W\u003c\/p\u003e\n\u003cp\u003e5.4 W 20 °C)\u003c\/p\u003e\n\u003cp\u003eholding power consumption in W\u003c\/p\u003e\n\u003cp\u003e5.4 W at 20 °C\u003c\/p\u003e\n\u003cp\u003eminimum switching voltage\u003c\/p\u003e\n\u003cp\u003e17 V\u003c\/p\u003e\n\u003cp\u003eminimum switching current\u003c\/p\u003e\n\u003cp\u003e5 mA\u003c\/p\u003e\n\u003cp\u003enon-overlap time\u003c\/p\u003e\n\u003cp\u003e1.5 ms on energization between NO and NC contact\u003c\/p\u003e\n\u003cp\u003e1.5 ms on de-energization between NO and NC contact\u003c\/p\u003e\n\u003cp\u003einsulation resistance\u003c\/p\u003e\n\u003cp\u003e\u0026gt; 10 MOhm\u003c\/p\u003e\n\u003cp\u003eMechanical robustness\u003c\/p\u003e\n\u003cp\u003eShocks open control relay: 10 Gn for 11 ms conforming to IEC 60068-2-27\u003c\/p\u003e\n\u003cp\u003eShocks closed control relay: 15 Gn for 11 ms conforming to IEC 60068-2-27\u003c\/p\u003e\n\u003cp\u003eVibrations open control relay: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6\u003c\/p\u003e\n\u003cp\u003eVibrations closed control relay: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 03\/07\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 0.500\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10x15x24\u003c\/p\u003e\n\u003cp\u003eLocator: B1P2A\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ST (Tax Substitution) value may apply.\u003c\/p\u003e\n\u003cp\u003eIf the operation is subject to this tax, the responsibility for payment is solely the buyer's.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":46605935280365,"sku":"WS3582","price":142.5,"currency_code":"BRL","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/contator-auxiliar-schneider-cad32gd-10a-125vdc-3na-2nf_1.jpg?v=1782405876","url":"https:\/\/caboeletro.com\/en\/products\/schneider-auxiliary-contactor-cad32gd-10a-125vdc-3no-2nc","provider":"Cabo Eletro","version":"1.0","type":"link"}