{"product_id":"rele-inteligente-telemecanique-ltmr08dfm-0-48a-100-240v","title":"Smart Relay TELEMECANIQUE LTMR08DFM 0.48A 100-240V","description":"\u003cp\u003eTELEMECHANIQUE LTMR08DFM Smart Relay 0.48A 100-240v\u003c\/p\u003e\n\u003cp\u003eUSED product out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: TELEMECANIQUE\u003c\/p\u003e\n\u003cp\u003eModel: LTMR08DFM\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTESYS T DEVICENET SMART RELAY 0.48A 100240VCA LTMR08DFM\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA smart relay is an advanced version of a conventional relay that includes additional control, monitoring, and communication features. These additional features allow the smart relay to perform more sophisticated functions and offer greater automation and integration capabilities with other systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThey are widely used in electrical power distribution systems, industrial automation, energy monitoring and control systems, among other applications where advanced control, monitoring, and protection functionalities are required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTeSys T is a motor management system that provides complete motor monitoring, control, and protection when used with short-circuit protection and a contactor. TeSys T manages the most critical processes, reducing downtime and increasing productivity. TeSys T is a flexible system that seamlessly integrates into your automation system through five main communication protocols. TeSys T anticipates what will happen in the process, as it accurately monitors current, voltage, and power across a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages three-phase current measurement via integrated current transformers from 0.4 to 100 A or up to 810 A via external current transformers. It also measures ground current with internal or external ground sensors, motor temperature, and inputs and outputs for the various motor control modes, management of detected faults, and other functions. The DeviceNet protocol is used by this controller. This module has 6 discrete logical inputs, 3 relay logical outputs, and one relay output for signaling detected fault overload relay. The current range of this controller is 0.4 to 8 amperes. 120 to 240 VAC is used to power this controller. The controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick, and CCC.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003eLine\u003c\/p\u003e\n\u003cp\u003eTeSys\u003c\/p\u003e\n\u003cp\u003eProduct name\u003c\/p\u003e\n\u003cp\u003eTeSys T\u003c\/p\u003e\n\u003cp\u003eDevice short name\u003c\/p\u003e\n\u003cp\u003eLTMR\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eMotor controller\u003c\/p\u003e\n\u003cp\u003eDevice application\u003c\/p\u003e\n\u003cp\u003eEquipment monitoring and control\u003c\/p\u003e\n\u003cp\u003eMeasuring current\u003c\/p\u003e\n\u003cp\u003e0.4…8 A\u003c\/p\u003e\n\u003cp\u003eRated supply voltage [Us]\u003c\/p\u003e\n\u003cp\u003e100...240 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eCurrent consumption\u003c\/p\u003e\n\u003cp\u003e8...62.8 mA\u003c\/p\u003e\n\u003cp\u003eSupply voltage limits\u003c\/p\u003e\n\u003cp\u003e93.5…264 V AC\u003c\/p\u003e\n\u003cp\u003eCommunication port protocol\u003c\/p\u003e\n\u003cp\u003eDeviceNet\u003c\/p\u003e\n\u003cp\u003eBus type\u003c\/p\u003e\n\u003cp\u003eDeviceNet ISO 1198 interface Addressing 1...64, Transmission Rate 125...500 kbit\/s, terminal block with 4 shielded twisted pair cables\u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e690 V conforming to EN\/IEC 60947-1\u003c\/p\u003e\n\u003cp\u003e690 V conforming to CSA C22.2 No 14\u003c\/p\u003e\n\u003cp\u003e690 V conforming to UL 508\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e4 kV supply, inputs and outputs conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003e6 kV current or voltage measurement circuit conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003e0.8 kV communication circuit conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eShort-circuit withstand\u003c\/p\u003e\n\u003cp\u003e100 kA conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eAssociated fuse rating\u003c\/p\u003e\n\u003cp\u003e4 A gG for Output\u003c\/p\u003e\n\u003cp\u003e0.5 A gG for control circuit\u003c\/p\u003e\n\u003cp\u003eProtection type\u003c\/p\u003e\n\u003cp\u003eThermal overload protection\u003c\/p\u003e\n\u003cp\u003ePhase failure\u003c\/p\u003e\n\u003cp\u003eOverload\u003c\/p\u003e\n\u003cp\u003eLoad fluctuation\u003c\/p\u003e\n\u003cp\u003ePower factor variation\u003c\/p\u003e\n\u003cp\u003eOverload (time)\u003c\/p\u003e\n\u003cp\u003eEarth leakage protection\u003c\/p\u003e\n\u003cp\u003eReverse polarity protection\u003c\/p\u003e\n\u003cp\u003eThermal protection\u003c\/p\u003e\n\u003cp\u003ePhase imbalance\u003c\/p\u003e\n\u003cp\u003eLocked rotor\u003c\/p\u003e\n\u003cp\u003eNetwork type and machine diagnostics\u003c\/p\u003e\n\u003cp\u003eOperating hours \/ operational time counter\u003c\/p\u003e\n\u003cp\u003eStarting current and time\u003c\/p\u003e\n\u003cp\u003eFault recording\u003c\/p\u003e\n\u003cp\u003eTrip history information\u003c\/p\u003e\n\u003cp\u003eTrip context information\u003c\/p\u003e\n\u003cp\u003ePhase and earth fault odometers\u003c\/p\u003e\n\u003cp\u003eMotor control command recording\u003c\/p\u003e\n\u003cp\u003eEvent recording\u003c\/p\u003e\n\u003cp\u003eWaiting time after overload trip\u003c\/p\u003e\n\u003cp\u003eRemaining operating time before overload trip\u003c\/p\u003e\n\u003cp\u003eNumber of logical inputs\u003c\/p\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003cp\u003eInput current\u003c\/p\u003e\n\u003cp\u003e3.1 mA at 100 V\u003c\/p\u003e\n\u003cp\u003e7.5 mA at 240 V\u003c\/p\u003e\n\u003cp\u003eCurrent state 0 guaranteed\u003c\/p\u003e\n\u003cp\u003eLogic input: 0...40 V and \u003c= 15 mA for 25 ms\u003c\/p\u003e\n\u003cp\u003eCurrent state 1 guaranteed\u003c\/p\u003e\n\u003cp\u003eLogic input: 79...264 V and \u003e= 2 mA for 25 ms\u003c\/p\u003e\n\u003cp\u003eMaximum output switching frequency\u003c\/p\u003e\n\u003cp\u003e2 Hz\u003c\/p\u003e\n\u003cp\u003eLoad current\u003c\/p\u003e\n\u003cp\u003e5 A at 250 V AC for logic output\u003c\/p\u003e\n\u003cp\u003e5 A at 30 V DC for logic output\u003c\/p\u003e\n\u003cp\u003eAllowable power\u003c\/p\u003e\n\u003cp\u003e480 VA (AC-15), Ie = 2 A, 500000 cycles (Output)\u003c\/p\u003e\n\u003cp\u003e30 W (DC-13), Ie = 1.25 A, 500000 cycles (Output)\u003c\/p\u003e\n\u003cp\u003eMaximum operating rate\u003c\/p\u003e\n\u003cp\u003e1800 cycles\/h\u003c\/p\u003e\n\u003cp\u003eContact type and composition\u003c\/p\u003e\n\u003cp\u003e1 NO + 1 NC fault signal\u003c\/p\u003e\n\u003cp\u003e3 NO\u003c\/p\u003e\n\u003cp\u003eMeasurement type\u003c\/p\u003e\n\u003cp\u003eCurrent imbalance\u003c\/p\u003e\n\u003cp\u003eEarth fault current\u003c\/p\u003e\n\u003cp\u003eIavg average current\u003c\/p\u003e\n\u003cp\u003eTemperature\u003c\/p\u003e\n\u003cp\u003eI1 phase current, I2, I3 RMS\u003c\/p\u003e\n\u003cp\u003eMeasurement accuracy\u003c\/p\u003e\n\u003cp\u003e5...15% internal earth fault current measurement\u003c\/p\u003e\n\u003cp\u003e1% Voltage (100..830 V)\u003c\/p\u003e\n\u003cp\u003e3% Power factor\u003c\/p\u003e\n\u003cp\u003e5% external earth fault current measurement\u003c\/p\u003e\n\u003cp\u003e+\/- 30 min\/year internal clock\u003c\/p\u003e\n\u003cp\u003e0.02 Temperature\u003c\/p\u003e\n\u003cp\u003e1% Current\u003c\/p\u003e\n\u003cp\u003e5% active and reactive power\u003c\/p\u003e\n\u003cp\u003eOvervoltage category\u003c\/p\u003e\n\u003cp\u003eIII\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 2024-04-17\u003c\/p\u003e\n\u003cp\u003eWeight: 0.450Kg\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10X15X24\u003c\/p\u003e\n\u003cp\u003eLocator: A10P2B\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ST (Substituição Tributária - Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment is solely that of the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Telemecanique","offers":[{"title":"Default Title","offer_id":49727154061549,"sku":"WS4158","price":700.0,"currency_code":"BRL","in_stock":true}],"url":"https:\/\/caboeletro.com\/en\/products\/rele-inteligente-telemecanique-ltmr08dfm-0-48a-100-240v","provider":"Cabo Eletro","version":"1.0","type":"link"}