{"product_id":"rele-inteligente-schneider-ltmr100ebd-5100a-24vdc","title":"Schneider LTMR100EBD 5100A 24VDC Smart Relay","description":"\u003cp\u003eSCHNEIDER LTMR100EBD 5100A 24VDC Smart Relay\u003c\/p\u003e\n\u003cp\u003eUSED product out of the manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: SCHNEIDER\u003c\/p\u003e\n\u003cp\u003eModel: LTMR100EBD\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA smart relay is an advanced version of a conventional relay that includes additional control, monitoring, and communication features. These additional features allow the smart relay to perform more sophisticated functions and offer greater automation and integration capabilities with other systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThey are widely used in electrical power distribution systems, industrial automation, power monitoring and control systems, among other applications where advanced control, monitoring, and protection functionalities are required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTESYS T ETHERNET SMART RELAY 5100A 24VDC LTMR100EBD\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTeSys T is a motor management system that provides comprehensive motor monitoring, control, and protection when used with short-circuit protection and a contactor. TeSys T manages the most critical processes, reducing downtime and increasing productivity. TeSys T is a flexible system that seamlessly integrates into your automation system via five main communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power across a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages three-phase current measurement via integrated current transformers from 0.4 to 100 A or up to 810 A via external current transformers. It also measures earth current with internal or external earth sensors, motor temperature, and inputs and outputs for various motor control modes, management of detected faults, and other functions. The Ethernet\/IP and Modbus\/TCP protocol is used by this controller. Ethernet TCP\/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs, and one relay output for signaling detected fault overload relay.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003erange\u003c\/p\u003e\n\u003cp\u003eTeSys\u003c\/p\u003e\n\u003cp\u003eProduct name\u003c\/p\u003e\n\u003cp\u003eTeSys T\u003c\/p\u003e\n\u003cp\u003eDevice short name\u003c\/p\u003e\n\u003cp\u003eLTMR\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eMotor controller\u003c\/p\u003e\n\u003cp\u003eDevice application\u003c\/p\u003e\n\u003cp\u003eEquipment monitoring and control\u003c\/p\u003e\n\u003cp\u003eMeasuring current\u003c\/p\u003e\n\u003cp\u003e5…100 A\u003c\/p\u003e\n\u003cp\u003eRated supply voltage [Us]\u003c\/p\u003e\n\u003cp\u003e24 V DC\u003c\/p\u003e\n\u003cp\u003eCurrent consumption\u003c\/p\u003e\n\u003cp\u003e56...127 mA\u003c\/p\u003e\n\u003cp\u003esupply voltage limits\u003c\/p\u003e\n\u003cp\u003e20.4…26.24 V DC\u003c\/p\u003e\n\u003cp\u003eCommunication port protocol\u003c\/p\u003e\n\u003cp\u003eModbus TCP \/ Ethernet \/ IP\u003c\/p\u003e\n\u003cp\u003ebus type\u003c\/p\u003e\n\u003cp\u003eEthernet IEEE 802.3 interface Addressing 0...159, Transmission rate 10...100 Mbit\/s, RJ45 with 2 shielded twisted pairs\u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e690 V conforming to EN\/IEC 60947-1\u003c\/p\u003e\n\u003cp\u003e690 V conforming to CSA C22.2 No 14\u003c\/p\u003e\n\u003cp\u003e690 V conforming to UL 508\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e6 kV current or voltage measuring circuit conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003e0.8 kV communication circuit conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003e0.8 kV supply, inputs and outputs conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eshort-circuit resistance\u003c\/p\u003e\n\u003cp\u003e100 kA conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eassociated fuse rating\u003c\/p\u003e\n\u003cp\u003e4 A gG for Output\u003c\/p\u003e\n\u003cp\u003e0.5 A gG for control circuit\u003c\/p\u003e\n\u003cp\u003eProtection type\u003c\/p\u003e\n\u003cp\u003eLocked rotor\u003c\/p\u003e\n\u003cp\u003eOverload\u003c\/p\u003e\n\u003cp\u003eThermal overload protection\u003c\/p\u003e\n\u003cp\u003eEarth leakage protection\u003c\/p\u003e\n\u003cp\u003eReverse polarity protection\u003c\/p\u003e\n\u003cp\u003eOverload (time)\u003c\/p\u003e\n\u003cp\u003ePower factor variation\u003c\/p\u003e\n\u003cp\u003ePhase imbalance\u003c\/p\u003e\n\u003cp\u003eLoad fluctuation\u003c\/p\u003e\n\u003cp\u003ePhase failure\u003c\/p\u003e\n\u003cp\u003eThermal protection\u003c\/p\u003e\n\u003cp\u003eNetwork type and machine diagnostics\u003c\/p\u003e\n\u003cp\u003eFault recording\u003c\/p\u003e\n\u003cp\u003eTrip context information\u003c\/p\u003e\n\u003cp\u003eWaiting time after overload trip\u003c\/p\u003e\n\u003cp\u003eTrip history information\u003c\/p\u003e\n\u003cp\u003eOperating hours \/ operational time counter\u003c\/p\u003e\n\u003cp\u003eMotor control command recording\u003c\/p\u003e\n\u003cp\u003eStarting current and time\u003c\/p\u003e\n\u003cp\u003ePhase and earth fault odometers\u003c\/p\u003e\n\u003cp\u003eEvent recording\u003c\/p\u003e\n\u003cp\u003eRemaining operational time before overload trip\u003c\/p\u003e\n\u003cp\u003enumber of logic inputs\u003c\/p\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003cp\u003einput current\u003c\/p\u003e\n\u003cp\u003e7 mA\u003c\/p\u003e\n\u003cp\u003eCurrent state 0 guaranteed\u003c\/p\u003e\n\u003cp\u003eLogic input: \u003c 5 V and \u003c= 15 mA of 5 ms\u003c\/p\u003e\n\u003cp\u003eCurrent state 1 guaranteed\u003c\/p\u003e\n\u003cp\u003eLogic input: \u003c 15 V and 2...15 mA of 15 ms\u003c\/p\u003e\n\u003cp\u003emaximum output switching frequency\u003c\/p\u003e\n\u003cp\u003e2 Hz\u003c\/p\u003e\n\u003cp\u003eload current\u003c\/p\u003e\n\u003cp\u003e5 A at 250 V AC of logic output\u003c\/p\u003e\n\u003cp\u003e5 A at 30 V DC of logic output\u003c\/p\u003e\n\u003cp\u003eadmissible power\u003c\/p\u003e\n\u003cp\u003e480 VA (AC-15), Ie = 2 A, 500000 cycles (Output)\u003c\/p\u003e\n\u003cp\u003e30 W (DC-13), Ie = 1.25 A, 500000 cycles (Output)\u003c\/p\u003e\n\u003cp\u003emaximum operating rate\u003c\/p\u003e\n\u003cp\u003e1800 cyc\/h\u003c\/p\u003e\n\u003cp\u003econtact type and composition\u003c\/p\u003e\n\u003cp\u003e1 NO + 1 NC fault signal\u003c\/p\u003e\n\u003cp\u003e3 NO\u003c\/p\u003e\n\u003cp\u003emeasurement type\u003c\/p\u003e\n\u003cp\u003eIavg average current\u003c\/p\u003e\n\u003cp\u003eEarth fault current\u003c\/p\u003e\n\u003cp\u003eTemperature\u003c\/p\u003e\n\u003cp\u003eI1 phase current, I2, I3 RMS\u003c\/p\u003e\n\u003cp\u003eCurrent unbalance\u003c\/p\u003e\n\u003cp\u003emeasurement accuracy\u003c\/p\u003e\n\u003cp\u003e5...15 % internal earth fault current measurement\u003c\/p\u003e\n\u003cp\u003e1 % Voltage (100...830 V)\u003c\/p\u003e\n\u003cp\u003e3 % Power factor\u003c\/p\u003e\n\u003cp\u003e5 % external earth fault current measurement\u003c\/p\u003e\n\u003cp\u003e+\/- 30 min\/year internal clock\u003c\/p\u003e\n\u003cp\u003e0.02 Temperature\u003c\/p\u003e\n\u003cp\u003e5 % active and reactive power\u003c\/p\u003e\n\u003cp\u003e0.02 Current\u003c\/p\u003e\n\u003cp\u003eOvervoltage category\u003c\/p\u003e\n\u003cp\u003eIII\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 04\/17\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 0.460Kg\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10X15X24\u003c\/p\u003e\n\u003cp\u003eLocator: A1P2B\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ST (Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment is exclusively the buyer's.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":49727153766637,"sku":"WS4176","price":800.0,"currency_code":"BRL","in_stock":true}],"url":"https:\/\/caboeletro.com\/en\/products\/rele-inteligente-schneider-ltmr100ebd-5100a-24vdc","provider":"Cabo Eletro","version":"1.0","type":"link"}