{"product_id":"rele-inteligente-schneider-ltmr08pbd-24vdc-0-6kv","title":"Schneider Intelligent Relay LTMR08PBD 24Vdc 0.6kV","description":"\u003cp\u003eSchneider LTMR08PBD 24Vdc 0.6kV Smart Relay\u003c\/p\u003e\n\u003cp\u003eNEW product in manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: SCHNEIDER\u003c\/p\u003e\n\u003cp\u003eModel: LTMR08PBD\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTESYS T PROFIBUS DP SMART RELAY 0.48A 24VDC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA smart relay is a control and protection device used in electrical systems that incorporates advanced monitoring, communication, and analysis features to ensure more efficient, reliable, and safe operation of the electrical system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003cp\u003eTeSys\u003c\/p\u003e\n\u003cp\u003eProduct name\u003c\/p\u003e\n\u003cp\u003eTeSys T\u003c\/p\u003e\n\u003cp\u003eDevice short name\u003c\/p\u003e\n\u003cp\u003eLTMR\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eMotor controller\u003c\/p\u003e\n\u003cp\u003eDevice application\u003c\/p\u003e\n\u003cp\u003eEquipment monitoring and control\u003c\/p\u003e\n\u003cp\u003eMeasurement current\u003c\/p\u003e\n\u003cp\u003e0.4…8 A\u003c\/p\u003e\n\u003cp\u003eRated supply voltage [Us]\u003c\/p\u003e\n\u003cp\u003e24 V DC\u003c\/p\u003e\n\u003cp\u003eCurrent consumption\u003c\/p\u003e\n\u003cp\u003e56...127 mA\u003c\/p\u003e\n\u003cp\u003eSupply voltage limits\u003c\/p\u003e\n\u003cp\u003e20.4…26.24 V DC\u003c\/p\u003e\n\u003cp\u003eCommunication port protocol\u003c\/p\u003e\n\u003cp\u003eProfibus DP\u003c\/p\u003e\n\u003cp\u003eBus type\u003c\/p\u003e\n\u003cp\u003eProfibus DP RS485 2-wire polarized interface Addressing 1...125, Transmission rate 9.6 kbit\/s...12 Mbit\/s, SUB-D 9 with 2 shielded twisted pairs, type A\u003c\/p\u003e\n\u003cp\u003eProfibus DP RS485 2-wire polarized interface Addressing 1...125, Transmission rate 9.6 kbit\/s...12 Mbit\/s, terminal block with 2 shielded twisted pairs, type A\u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e690 V conforming to EN\/IEC 60947-1\u003c\/p\u003e\n\u003cp\u003e690 V conforming to CSA C22.2 No 14\u003c\/p\u003e\n\u003cp\u003e690 V conforming to UL 508\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e6 kV current or voltage measurement circuit conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003e0.8 kV communication circuit conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003e0.8 kV supply, inputs and outputs conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eShort-circuit withstand\u003c\/p\u003e\n\u003cp\u003e100 kA conforming to EN\/IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eAssociated fuse rating\u003c\/p\u003e\n\u003cp\u003e4 A gG for Output\u003c\/p\u003e\n\u003cp\u003e0.5 A gG for control circuit\u003c\/p\u003e\n\u003cp\u003eProtection type\u003c\/p\u003e\n\u003cp\u003eThermal protection\u003c\/p\u003e\n\u003cp\u003eLoad fluctuation\u003c\/p\u003e\n\u003cp\u003ePower factor variation\u003c\/p\u003e\n\u003cp\u003ePhase failure\u003c\/p\u003e\n\u003cp\u003eOverload\u003c\/p\u003e\n\u003cp\u003eReverse polarity protection\u003c\/p\u003e\n\u003cp\u003eOverload (time)\u003c\/p\u003e\n\u003cp\u003eEarth leakage protection\u003c\/p\u003e\n\u003cp\u003eLocked rotor\u003c\/p\u003e\n\u003cp\u003eThermal overload protection\u003c\/p\u003e\n\u003cp\u003ePhase unbalance\u003c\/p\u003e\n\u003cp\u003eNetwork type and machine diagnosis\u003c\/p\u003e\n\u003cp\u003eMotor control command recording\u003c\/p\u003e\n\u003cp\u003eOperating time\/hours counter\u003c\/p\u003e\n\u003cp\u003eTrip history information\u003c\/p\u003e\n\u003cp\u003eFault recording\u003c\/p\u003e\n\u003cp\u003eStarting current and time\u003c\/p\u003e\n\u003cp\u003ePhase and earth fault odometers\u003c\/p\u003e\n\u003cp\u003eRemaining operating time before overload trip\u003c\/p\u003e\n\u003cp\u003eWait time after overload trip\u003c\/p\u003e\n\u003cp\u003eTrip context information\u003c\/p\u003e\n\u003cp\u003eEvent recording\u003c\/p\u003e\n\u003cp\u003eNumber of logical inputs\u003c\/p\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003cp\u003eInput current\u003c\/p\u003e\n\u003cp\u003e7 mA\u003c\/p\u003e\n\u003cp\u003eCurrent state 0 guaranteed\u003c\/p\u003e\n\u003cp\u003eLogic input: \u003c 5 V and \u003c= 15 mA for 5 ms\u003c\/p\u003e\n\u003cp\u003eCurrent state 1 guaranteed\u003c\/p\u003e\n\u003cp\u003eLogic input: \u003c 15 V and 2...15 mA for 15 ms\u003c\/p\u003e\n\u003cp\u003eMaximum output switching frequency\u003c\/p\u003e\n\u003cp\u003e2 Hz\u003c\/p\u003e\n\u003cp\u003eLoad current\u003c\/p\u003e\n\u003cp\u003e5 A at 250 V AC for logic output\u003c\/p\u003e\n\u003cp\u003e5 A at 30 V DC for logic output\u003c\/p\u003e\n\u003cp\u003ePermissible power\u003c\/p\u003e\n\u003cp\u003e480 VA (AC-15), Ie = 2 A, 500000 cycles (Output)\u003c\/p\u003e\n\u003cp\u003e30 W (DC-13), Ie = 1.25 A, 500000 cycles (Output)\u003c\/p\u003e\n\u003cp\u003eMaximum operating rate\u003c\/p\u003e\n\u003cp\u003e1800 cyc\/h\u003c\/p\u003e\n\u003cp\u003eType and composition of contacts\u003c\/p\u003e\n\u003cp\u003e1 NO + 1 NC fault signal\u003c\/p\u003e\n\u003cp\u003e3 NO\u003c\/p\u003e\n\u003cp\u003eMeasurement type\u003c\/p\u003e\n\u003cp\u003eEarth fault current\u003c\/p\u003e\n\u003cp\u003eIavg average current\u003c\/p\u003e\n\u003cp\u003eCurrent unbalance\u003c\/p\u003e\n\u003cp\u003eI1 phase current, I2, I3 RMS\u003c\/p\u003e\n\u003cp\u003eTemperature\u003c\/p\u003e\n\u003cp\u003eMeasurement accuracy\u003c\/p\u003e\n\u003cp\u003e5...15 % internal earth fault current measurement\u003c\/p\u003e\n\u003cp\u003e1 % Voltage (100...830 V)\u003c\/p\u003e\n\u003cp\u003e3 % Power factor\u003c\/p\u003e\n\u003cp\u003e5 % external earth fault current measurement\u003c\/p\u003e\n\u003cp\u003e+\/- 30 min\/year internal clock\u003c\/p\u003e\n\u003cp\u003e0.02 Temperature\u003c\/p\u003e\n\u003cp\u003e1 % Current\u003c\/p\u003e\n\u003cp\u003e5 % active and reactive power\u003c\/p\u003e\n\u003cp\u003eOvervoltage category\u003c\/p\u003e\n\u003cp\u003eIII\u003c\/p\u003e\n\u003cp\u003eDate: 04\/18\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 0.450Kg\u003c\/p\u003e\n\u003cp\u003eMeasurements: 14X10X8\u003c\/p\u003e\n\u003cp\u003eLocator: B1P2B\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is for resale, ST (Tax Substitution) may apply. If the operation is subject to this tax, the responsibility for payment lies solely with the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":49727114281197,"sku":"WS3967","price":3000.0,"currency_code":"BRL","in_stock":true}],"url":"https:\/\/caboeletro.com\/en\/products\/rele-inteligente-schneider-ltmr08pbd-24vdc-0-6kv","provider":"Cabo Eletro","version":"1.0","type":"link"}