{"product_id":"protetor-contra-surtos-phoenix-pt-2-pe-s-120ac-st-26a-150v","title":"Phoenix Surge Protector PT 2-PE\/S 120AC-ST 26A 150V","description":"\u003cp\u003ePhoenix Contact PT 2-PE\/S 120AC-ST 26A 150V Surge Protector\u003c\/p\u003e\n\u003cp\u003eNew product out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: Phoenix Contact\u003c\/p\u003e\n\u003cp\u003eModel: PT 2-PE\/S 120AC-ST\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA surge protector, also known as a surge suppressor or SPD (Surge Protective Device), is a device designed to protect electronic and electrical equipment from damage caused by transient voltage spikes, known as electrical surges.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eElectrical surges are rapid and transient increases in electrical voltage that can occur in the electrical grid due to various reasons, such as lightning strikes, switching operations in the electrical grid, switching of high-power equipment, and failures in electrical devices. These surges can reach very high voltage levels and cause significant damage to equipment connected to the electrical grid.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe main function of a surge protector is to detect and divert the excessive energy of electrical surges, ensuring that they do not reach the sensitive equipment connected to it. The device has components that are capable of responding quickly to electrical surges, diverting them to the ground, where the energy is safely dissipated.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA surge protector is usually connected between the electrical power source and the equipment to be protected, such as computers, household appliances, entertainment systems, telecommunications equipment, and other sensitive electronic devices. It provides a protective barrier, intercepting and redirecting surges away from connected devices, thereby preventing damage to them.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIt is important to note that a surge protector cannot provide absolute protection against all types of electrical damage. If a surge is exceptionally strong or close, there may be an overload that exceeds the protector's capacity. Furthermore, these devices have a limited lifespan and may lose their effectiveness over time. Therefore, it is recommended to replace surge protectors periodically.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn summary, a surge protector is a protective device that diverts and neutralizes electrical surges to protect electronic and electrical equipment from damage. It plays a fundamental role in protecting devices connected to the electrical grid from voltage spikes, extending their lifespan and ensuring their safe operation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eType\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003eMale\u003c\/p\u003e\n\u003cp\u003eProduct type\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003eDevice protection\u003c\/p\u003e\n\u003cp\u003eNumber of positions\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e2\u003c\/p\u003e\n\u003cp\u003eSurge protection fault message\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003eOptical remote indication contact\u003c\/p\u003e\n\u003cp\u003eInsulation characteristics\u003c\/p\u003e\n\u003cp\u003eOvervoltage category\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003eIII\u003c\/p\u003e\n\u003cp\u003eDegree of pollution\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e2\u003c\/p\u003e\n\u003cp\u003eThe lightning arrester can be tested with CHECKMASTER from software version:\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003eFrom SW rev. 1.00\u003c\/p\u003e\n\u003cp\u003eIEC test classification\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003eIII\u003c\/p\u003e\n\u003cp\u003eT3\u003c\/p\u003e\n\u003cp\u003eEN type\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003eT3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDirection of action\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e1L-N \u0026 N-PE\u003c\/p\u003e\n\u003cp\u003eRated frequency f N\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e50 Hz\u003c\/p\u003e\n\u003cp\u003e60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum continuous voltage U C\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e150 V AC\u003c\/p\u003e\n\u003cp\u003eRated load current I L\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e26 A (30°C)\u003c\/p\u003e\n\u003cp\u003eResidual current I PE\u003cspan style=\"white-space: pre;\"\u003e \u0026lt; \u003c\/span\u003e2 UA\u003c\/p\u003e\n\u003cp\u003eStandby power consumption P C\u003cspan style=\"white-space: pre;\"\u003e \u0026lt;\u003c\/span\u003e 200 mVA\u003c\/p\u003e\n\u003cp\u003eEffective operating current I C at U C\u003cspan style=\"white-space: pre;\"\u003e \u0026lt;\u003c\/span\u003e1.1 mA\u003c\/p\u003e\n\u003cp\u003eNominal discharge current In ( 8\/20) us\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e2.5 kA\u003c\/p\u003e\n\u003cp\u003e3 kA (according to UL 1449)\u003c\/p\u003e\n\u003cp\u003eVoltage protection level Up ( LN)\u003cspan style=\"white-space: pre;\"\u003e \u0026lt; \u003c\/span\u003e620 V\u003c\/p\u003e\n\u003cp\u003eVoltage protection level U p (L-PE)\u003cspan style=\"white-space: pre;\"\u003e \u0026lt;\u003c\/span\u003e 850 V\u003c\/p\u003e\n\u003cp\u003eVoltage protection level Up ( N-PE)\u003cspan style=\"white-space: pre;\"\u003e \u0026lt;\u003c\/span\u003e 850 V\u003c\/p\u003e\n\u003cp\u003eResidual voltage at In\u003cspan style=\"white-space: pre;\"\u003e \u0026lt;\u003c\/span\u003e 620 V\u003c\/p\u003e\n\u003cp\u003e\u0026lt; 330 V\u003c\/p\u003e\n\u003cp\u003e≤ 330 V\u003c\/p\u003e\n\u003cp\u003eResponse time t A (LN)\u003cspan style=\"white-space: pre;\"\u003e \u0026lt;\u003c\/span\u003e 25 ns\u003c\/p\u003e\n\u003cp\u003eResponse time t A (L-PE)\u003cspan style=\"white-space: pre;\"\u003e \u0026lt;\u003c\/span\u003e 100 ns\u003c\/p\u003e\n\u003cp\u003eResponse time t A (N-PE)\u003cspan style=\"white-space: pre;\"\u003e \u0026lt;\u003c\/span\u003e 100 ns\u003c\/p\u003e\n\u003cp\u003eMax. backup fuse required\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e25 A (gL)\u003c\/p\u003e\n\u003cp\u003e25 A (MCB 25 AB\/C)\u003c\/p\u003e\n\u003cp\u003eShort-circuit withstand capability I P with max. backup fuse (rms)\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e1.5 kA\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 05\/19\/2023\u003c\/p\u003e\n\u003cp\u003eWeight: 0.022\u003c\/p\u003e\n\u003cp\u003eMeasurements: 5x4x2\u003c\/p\u003e\n\u003cp\u003eLocator: B2P2C\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ST (Substituição Tributária) value may be applied. If the transaction is subject to this tax, the responsibility for payment lies solely with the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial ltda thanks you\u003c\/p\u003e","brand":"PHOENIX CONTACT","offers":[{"title":"Default Title","offer_id":49757855940845,"sku":"WS114","price":100.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/17c985764fc021f804ab89c626423782.jpg?v=1775502174","url":"https:\/\/caboeletro.com\/en\/products\/protetor-contra-surtos-phoenix-pt-2-pe-s-120ac-st-26a-150v","provider":"Cabo Eletro","version":"1.0","type":"link"}