{"product_id":"modulo-de-interface-smar-dfi302-df58-rs232-rs485","title":"Smar DFI302 DF58 RS232\/RS485 Interface Module","description":"\u003cp\u003eSmar DFI302 DF58 RS232\/RS485 Interface Module\u003c\/p\u003e\n\u003cp\u003eNew product in manufacturer's box\u003cbr\u003eBrand: SMAR\u003cbr\u003eModel: DFI302 DF58\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eDFI302 is a key element in the distributed architecture of field control systems. It combines powerful communication features with direct I\/O access and advanced control for continuous and discrete applications. Thanks to its modular concept, the DFI302 can be installed in panels in control rooms or in sealed enclosures in the field. It is highly expandable and suitable for small applications and\/or large and complex plants.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe DFI302 is a modular multifunction equipment, mounted on a backplane, connected to a DIN rail, where all modules are installed, including the Main (DF50) and Fieldbus (DF52) Power Supplies, Controllers (DF63, DF73, DF95 and DF97) and Line Impedance (DF53). The modules are secured using industrial connectors and a robust metal screw. Optionally, a conventional I\/O subsystem, with modules for analog and discrete inputs and outputs, can be connected. Modularity is the key to DFI302's flexibility. Furthermore, considering that all equipment is in modules and on the same backplane, the DFI302 can be considered fully integrated.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eA - Basic Installation and Configuration\u003c\/p\u003e\n\u003cp\u003eThis part contains all basic and general information about the installation of controllers, racks, I\/O modules, IP configuration, OPC servers, firmware updates, project types, and general information about adding functional and flexible blocks.\u003c\/p\u003e\n\u003cp\u003eHere you can also find information for troubleshooting, the FSR (Request for Review Form) and the warranty term for purchased products.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe file is composed of the following sections:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eOverview\u003c\/p\u003e\n\u003cp\u003eInstalling\u003c\/p\u003e\n\u003cp\u003eConfiguring\u003c\/p\u003e\n\u003cp\u003eConfiguring OPC servers\u003c\/p\u003e\n\u003cp\u003eConfiguring strategies\u003c\/p\u003e\n\u003cp\u003eAdding functional blocks\u003c\/p\u003e\n\u003cp\u003eAdding logic using flexible functional blocks\u003c\/p\u003e\n\u003cp\u003eAdding I\/O modules\u003c\/p\u003e\n\u003cp\u003eInstalling racks and their accessories\u003c\/p\u003e\n\u003cp\u003eTroubleshooting\u003c\/p\u003e\n\u003cp\u003eAppendices (FSR and Warranty Term)\u003c\/p\u003e\n\u003cp\u003eB - Technical Specifications\u003c\/p\u003e\n\u003cp\u003eThis part contains all technical specifications of the hardware components of the DFI302 platform. These are:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eControllers – DF63, DF73, DF75, DF89, DF95, DF97 and DF100.\u003c\/p\u003e\n\u003cp\u003eEthernet, serial and rack interconnection cables.\u003c\/p\u003e\n\u003cp\u003ePower supplies – DF50, DF53\/98, DF52\/60, DF56.\u003c\/p\u003e\n\u003cp\u003eInterfaces – DF58 and DF61\u003c\/p\u003e\n\u003cp\u003eThe file is composed of the following sections:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eTechnical specifications for controllers\u003c\/p\u003e\n\u003cp\u003eCable specifications\u003c\/p\u003e\n\u003cp\u003eAdding power supplies\u003c\/p\u003e\n\u003cp\u003eAdding interfaces\u003c\/p\u003e\n\u003cp\u003eC - Modbus\u003c\/p\u003e\n\u003cp\u003eThis part contains information for integrating systems that use the Modbus protocol into the DFI302 automation platform.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe file is composed of the following section:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eAdding Modbus\u003c\/p\u003e\n\u003cp\u003eD - Configuring Strategies with HSE\/FF Controllers\u003c\/p\u003e\n\u003cp\u003eThis part contains information for creating control strategies that use DF63 as a controller.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe file is composed of the following section:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eCreating a FOUNDATION fieldbus strategy using DF63\u003c\/p\u003e\n\u003cp\u003eE - Configuring Strategies with HSE\/PROFIBUS Controllers\u003c\/p\u003e\n\u003cp\u003eThis part contains information for creating control strategies that use DF73, DF95 or DF97 as controllers. Whereas:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe DF73 is the HSE\/Profibus-DP controller with 2 100 Mbps Ethernet ports and 1 Profibus DP channel.\u003c\/p\u003e\n\u003cp\u003eThe DF95 is the HSE\/Profibus controller with 2 100 Mbps Ethernet ports, 1 serial port, 2 Profibus PA ports and 1 Profibus DP channel.\u003c\/p\u003e\n\u003cp\u003eThe DF97 is the HSE\/Profibus controller with 2 100 Mbps Ethernet ports, 1 serial port, 4 Profibus PA ports and 1 Profibus DP channel.\u003c\/p\u003e\n\u003cp\u003eThe file is composed of the following section:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eCreating a configuration using DF73, DF95 or DF97\u003c\/p\u003e\n\u003cp\u003eF - Configuring Strategies with Modbus Controllers\u003c\/p\u003e\n\u003cp\u003eThis part contains information for creating control strategies that use DF89 as a controller.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe DF89 is the HSE\/Modbus controller with 2 100 Mbps Ethernet ports and 1 RS-232\/RS-485 Modbus RTU port.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eIt is composed of the following section:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eCreating a Modbus configuration using DF89\u003c\/p\u003e\n\u003cp\u003eG - Configuring Strategies with HSE\/WirelessHART Controllers\u003c\/p\u003e\n\u003cp\u003eThis part contains information for creating control strategies that use DF100 as a controller.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe DF100 is the HSE\/WirelessHART™ controller with 2 100 Mbps Ethernet ports, 1 RS-485 port and 1 WirelessHART channel\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eIt is composed of the following section:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eCreating a FOUNDATION fieldbus strategy using DF100\u003c\/p\u003e\n\u003cp\u003eH - Redundancy\u003c\/p\u003e\n\u003cp\u003eTo meet the requirements of fault tolerance, high availability and industrial process safety, DF63, DF73, DF75, DF89, DF95 and DF97 controllers work with the Hot Standby redundancy strategy.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThis section will provide information on how to properly install and configure the redundant system using these controllers.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eIt is composed of the following sections:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eAdding redundancy to DFI302 HSE controllers\u003c\/p\u003e\n\u003cp\u003eAdding redundancy with R-Series redundant input and output modules\u003c\/p\u003e\n\u003cp\u003eI - Conventional and Redundant Input\/Output Modules\u003c\/p\u003e\n\u003cp\u003eMany types of input\/output modules are available for the DFI302 automation platform, to meet a wide range of applications in the process control and automation industry.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe available types are:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eDiscrete inputs and outputs\u003c\/p\u003e\n\u003cp\u003eCombined discrete inputs and outputs\u003c\/p\u003e\n\u003cp\u003ePulse inputs\u003c\/p\u003e\n\u003cp\u003eAnalog inputs and outputs\u003c\/p\u003e\n\u003cp\u003eHART Inputs and Outputs\u003c\/p\u003e\n\u003cp\u003eRedundant Inputs and Outputs\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eDate: 10\/01\/19\u003cbr\u003eWeight: 0.426KG\u003cbr\u003eMeasurements: 5X18X24\u003cbr\u003eLocator: S2CL16P4\u003cbr\u003eA Cabo Eletro thanks you.\u003c\/p\u003e","brand":"SMAR","offers":[{"title":"Default Title","offer_id":49746579882221,"sku":"MLB1355484039","price":850.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/b539bcae6c625fb7004314a969666d8e.jpg?v=1775138034","url":"https:\/\/caboeletro.com\/en\/products\/modulo-de-interface-smar-dfi302-df58-rs232-rs485","provider":"Cabo Eletro","version":"1.0","type":"link"}