{"product_id":"drive-solenoide-pepperl-fuchs-kfd0-sd2-ex1-1045-24vdc","title":"Pepperl+Fuchs KFD0-SD2-Ex1.1045 24vDC Solenoid Driver","description":"\u003cp\u003ePepperl+Fuchs Solenoid Driver KFD0-SD2-Ex1.1045 24vDC\u003c\/p\u003e\n\u003cp\u003eUSED product out of the manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: PEPPERL+FUCHS\u003c\/p\u003e\n\u003cp\u003eModel: KFD0-SD2-EX1.1045 133240 20-35VDC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA Solenoid Driver is an electronic device or circuit used to control the operation of a solenoid. Solenoids are electromechanical actuators that convert electrical energy into linear mechanical motion, typically to operate valves, latches, or other mechanisms in industrial and automotive systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe solenoid driver provides the necessary electrical current to activate the solenoid, ensuring it operates safely and efficiently.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain function:\u003c\/p\u003e\n\u003cp\u003eControl the delivery of electrical power to the solenoid.\u003c\/p\u003e\n\u003cp\u003eProtect the circuit against overloads and voltage surges.\u003c\/p\u003e\n\u003cp\u003eRegulate current intensity to maintain optimal performance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cp\u003eIndustry:\u003c\/p\u003e\n\u003cp\u003eControl of pneumatic or hydraulic valves.\u003c\/p\u003e\n\u003cp\u003eAutomatic material handling machines.\u003c\/p\u003e\n\u003cp\u003eAutomotive:\u003c\/p\u003e\n\u003cp\u003eControl of valves in the engine.\u003c\/p\u003e\n\u003cp\u003eCentral locking systems.\u003c\/p\u003e\n\u003cp\u003eHousehold:\u003c\/p\u003e\n\u003cp\u003eWashing machines (water valve control).\u003c\/p\u003e\n\u003cp\u003eSecurity systems (electronic locks).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSolenoid driver KFD0-SD2-Ex2.1045\u003c\/p\u003e\n\u003cp\u003e2-channel isolated barrier\u003c\/p\u003e\n\u003cp\u003e24 V DC supply (loop powered)\u003c\/p\u003e\n\u003cp\u003eCurrent limit 45 mA at 10 V DC\u003c\/p\u003e\n\u003cp\u003eUp to SIL 3 acc. to IEC\/EN 61508\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eGeneral specifications\u003c\/p\u003e\n\u003cp\u003eSignal type Digital output\u003c\/p\u003e\n\u003cp\u003eFunctional safety related parameters\u003c\/p\u003e\n\u003cp\u003eSafety Integrity Level (SIL) SIL 3\u003c\/p\u003e\n\u003cp\u003eSupply\u003c\/p\u003e\n\u003cp\u003eRated voltage 20 ... 35 V DC, loop powered\u003c\/p\u003e\n\u003cp\u003ePower dissipation \u003c 1.05 W (\u003c 30 V) per channel\u003c\/p\u003e\n\u003cp\u003eInput\u003c\/p\u003e\n\u003cp\u003eConnection side control side\u003c\/p\u003e\n\u003cp\u003eConnection terminals 7, 8; 8, 9\u003c\/p\u003e\n\u003cp\u003eRated voltage 20 ... 35 V DC\u003c\/p\u003e\n\u003cp\u003eCurrent 72 mA with input voltage 20 V, load = 220\u003c\/p\u003e\n\u003cp\u003e50 mA with input voltage 35 V, load = 220\u003c\/p\u003e\n\u003cp\u003eStart-up current \u003c 200 mA after 100 µs\u003c\/p\u003e\n\u003cp\u003eOutput\u003c\/p\u003e\n\u003cp\u003eConnection side field side\u003c\/p\u003e\n\u003cp\u003eConnection terminals 1+, 2-; 4+, 5-\u003c\/p\u003e\n\u003cp\u003eInternal resistor max. 282\u003c\/p\u003e\n\u003cp\u003eCurrent \u003c 45 mA\u003c\/p\u003e\n\u003cp\u003eVoltage \u003e 10 V\u003c\/p\u003e\n\u003cp\u003eOpen circuit voltage min. 22.7V\u003c\/p\u003e\n\u003cp\u003eOutput current 45 mA\u003c\/p\u003e\n\u003cp\u003eOutput signal These values are valid for the nominal operating voltage 20 ... 35 V DC.\u003c\/p\u003e\n\u003cp\u003eSingle operation with energized\/de-energized delay: typ. 1.7ms\/50µs; periodic: typ. 5 µs\/50 µs\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 2025\/01\/06\u003c\/p\u003e\n\u003cp\u003eWeight: 0.300Kg\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10X15X24\u003c\/p\u003e\n\u003cp\u003eLocator: B10P3C\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ST (Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment rests exclusively with the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":49743992553709,"sku":"WS7659","price":300.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/4fe944f1ab1bf2d509ef4f7e785e7a20.jpg?v=1775067813","url":"https:\/\/caboeletro.com\/en\/products\/drive-solenoide-pepperl-fuchs-kfd0-sd2-ex1-1045-24vdc","provider":"Cabo Eletro","version":"1.0","type":"link"}