{"product_id":"disjuntor-tripolar-schneider-ng125h-16a-curva-c-380-415v-3p","title":"Schneider NG125H 16A C-Curve 380\/415V 3-Pole Circuit Breaker","description":"\u003cp\u003eSchneider NG125H 16A C Curve 380\/415v 3P Triple Pole Circuit Breaker\u003c\/p\u003e\n\u003cp\u003eNew product in manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: Schneider\u003c\/p\u003e\n\u003cp\u003eModel: NG125H 16A 18724\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNG125 - circuit breaker - NG125H - 3P - 16A - C curve\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis Acti9 NG125H product is a low voltage circuit breaker. It is a 3P circuit breaker with 3 protected poles and a rated current of 16A In and C tripping curve. The rated short-circuit breaking capacity is up to 36kA from 380 VAC to 415 VAC in compliance with EN\/IEC 60947-2 standard and 36 kA from 380 VAC to 415 VAC in compliance with EN\/IEC 60947-2 standard. It complies with the industrial standard EN\/IEC 60898-1 and the residential standard EN\/IEC 60947-2. This miniature circuit breaker protects circuits against short-circuit and overload current. It is suitable for isolation in the industrial sector according to IEC\/EN 60947-2 standard. Fault tripping is indicated by a red mechanical status indicator light on the front face of the circuit breaker. It has electrical endurance of up to 10,000 cycles and mechanical endurance of up to 20,000 cycles. The operational voltage Ue is less than or equal to 375VDC, 220VAC to 240VAC, 380VAC to 415VAC, 440VAC or 500VAC. The rated insulation voltage Ui is 690VAC. The rated impulse withstand voltage Uimp is 8kV. The operating frequency is 50 Hz or 60 Hz. It is DIN rail mountable. Its width is 9 x 9mm pitches. The pollution degree is 3. The overvoltage category is IV. The dimensions are (W) 81 mm x (H) 103 mm x (D) 81 mm. The weight is 0.72kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in the enclosure. The operating temperature is from -30°C to 70°C. The storage temperature is from -40°C to 70°C.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003eProduct line\u003c\/p\u003e\n\u003cp\u003eNG125\u003c\/p\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003cp\u003eActi9\u003c\/p\u003e\n\u003cp\u003eProduct Name\u003c\/p\u003e\n\u003cp\u003eActi9 NG125\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eMiniature circuit breaker\u003c\/p\u003e\n\u003cp\u003eDevice short name\u003c\/p\u003e\n\u003cp\u003eNG125H\u003c\/p\u003e\n\u003cp\u003eDevice application\u003c\/p\u003e\n\u003cp\u003eDistribution\u003c\/p\u003e\n\u003cp\u003ePoles description\u003c\/p\u003e\n\u003cp\u003e3P\u003c\/p\u003e\n\u003cp\u003eNumber of protected poles\u003c\/p\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003cp\u003e[In] rated current\u003c\/p\u003e\n\u003cp\u003e16 A at 40°C\u003c\/p\u003e\n\u003cp\u003eNetwork type\u003c\/p\u003e\n\u003cp\u003eDC\u003c\/p\u003e\n\u003cp\u003eAC\u003c\/p\u003e\n\u003cp\u003eTrip unit technology\u003c\/p\u003e\n\u003cp\u003eThermal-magnetic\u003c\/p\u003e\n\u003cp\u003eCurve code\u003c\/p\u003e\n\u003cp\u003eC\u003c\/p\u003e\n\u003cp\u003eBreaking capacity\u003c\/p\u003e\n\u003cp\u003e12 kA Icu at 500 V AC 50\/60 Hz conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e30 kA Icu at 440 V AC 50\/60 Hz conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e36 kA Icu at 380...415 V AC 50\/60 Hz conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e70 kA Icu at 220...240 V AC 50\/60 Hz conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e25 kA Icu at \u003c= 375 V DC conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eUtilisation category\u003c\/p\u003e\n\u003cp\u003eCategory A conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eSuitability for isolation\u003c\/p\u003e\n\u003cp\u003eYes, conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003eNetwork frequency\u003c\/p\u003e\n\u003cp\u003e50\/60Hz\u003c\/p\u003e\n\u003cp\u003e[Ue] rated operational voltage\u003c\/p\u003e\n\u003cp\u003e\u003c= 375 V DC\u003c\/p\u003e\n\u003cp\u003e380...415 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e500 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e220...240 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e440 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMagnetic tripping limit\u003c\/p\u003e\n\u003cp\u003e8 x In +\/- 20%\u003c\/p\u003e\n\u003cp\u003e[Ics] rated service breaking capacity\u003c\/p\u003e\n\u003cp\u003e52.5 kA 75% conforming to EN\/IEC 60947-2 - 220...240 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e27 kA 75% conforming to EN\/IEC 60947-2 - 380...415 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e22.5 kA 75% conforming to EN\/IEC 60947-2 - 440 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e9 kA 75% conforming to EN\/IEC 60947-2 - 500 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e25 kA 100% conforming to EN\/IEC 60947-2 - \u003c= 375 V DC\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e690 V AC 50\/60 Hz conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e8 kV conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eContact position indicator\u003c\/p\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003cp\u003eControl type\u003c\/p\u003e\n\u003cp\u003eToggle\u003c\/p\u003e\n\u003cp\u003eManual trip test\u003c\/p\u003e\n\u003cp\u003eLocal signalling\u003c\/p\u003e\n\u003cp\u003eTrip indicator\u003c\/p\u003e\n\u003cp\u003eON\/OFF indication\u003c\/p\u003e\n\u003cp\u003eMounting mode\u003c\/p\u003e\n\u003cp\u003eClip-on\u003c\/p\u003e\n\u003cp\u003eMounting support\u003c\/p\u003e\n\u003cp\u003e35 mm symmetrical DIN rail\u003c\/p\u003e\n\u003cp\u003eMounting position\u003c\/p\u003e\n\u003cp\u003eVertical\u003c\/p\u003e\n\u003cp\u003eBusbar and distribution block compatibility\u003c\/p\u003e\n\u003cp\u003eYES\u003c\/p\u003e\n\u003cp\u003e9 mm pitches\u003c\/p\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003cp\u003eHeight\u003c\/p\u003e\n\u003cp\u003e103 mm\u003c\/p\u003e\n\u003cp\u003eDepth\u003c\/p\u003e\n\u003cp\u003e81 mm\u003c\/p\u003e\n\u003cp\u003eWidth\u003c\/p\u003e\n\u003cp\u003e81 mm\u003c\/p\u003e\n\u003cp\u003eNet weight\u003c\/p\u003e\n\u003cp\u003e0.72kg\u003c\/p\u003e\n\u003cp\u003eMechanical durability\u003c\/p\u003e\n\u003cp\u003e20000 cycles\u003c\/p\u003e\n\u003cp\u003eElectrical durability\u003c\/p\u003e\n\u003cp\u003e10000 cycles\u003c\/p\u003e\n\u003cp\u003ePadlocking provision\u003c\/p\u003e\n\u003cp\u003eWith padlock\u003c\/p\u003e\n\u003cp\u003ePadlock options description\u003c\/p\u003e\n\u003cp\u003eIntegrated padlock\u003c\/p\u003e\n\u003cp\u003eConnections - terminals\u003c\/p\u003e\n\u003cp\u003eTunnel type terminals 1.5…50 mm² rigid\u003c\/p\u003e\n\u003cp\u003eTunnel type terminals 1…35 mm² flexible\u003c\/p\u003e\n\u003cp\u003eWire stripping length\u003c\/p\u003e\n\u003cp\u003e20mm\u003c\/p\u003e\n\u003cp\u003eTightening torque\u003c\/p\u003e\n\u003cp\u003e3.5 N.m\u003c\/p\u003e\n\u003cp\u003eEarth-leakage protection\u003c\/p\u003e\n\u003cp\u003eSeparate block\u003c\/p\u003e\n\u003cp\u003eEnvironment\u003c\/p\u003e\n\u003cp\u003eStandards\u003c\/p\u003e\n\u003cp\u003eEN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eIP degree of protection\u003c\/p\u003e\n\u003cp\u003eIP20 conforming to IEC 60529\u003c\/p\u003e\n\u003cp\u003eIK degree of protection\u003c\/p\u003e\n\u003cp\u003eIK05 conforming to EN\/IEC 62262\u003c\/p\u003e\n\u003cp\u003ePollution degree\u003c\/p\u003e\n\u003cp\u003e3 conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eOvervoltage category\u003c\/p\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003cp\u003eTropicalisation\u003c\/p\u003e\n\u003cp\u003e2 conforming to IEC 60068-1\u003c\/p\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003cp\u003e95% at 55°C\u003c\/p\u003e\n\u003cp\u003eAmbient air temperature for operation\u003c\/p\u003e\n\u003cp\u003e-30…70 °C\u003c\/p\u003e\n\u003cp\u003eAmbient air temperature for storage\u003c\/p\u003e\n\u003cp\u003e-40…70 °C\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 2024\/04\/17\u003c\/p\u003e\n\u003cp\u003eWeight: 0.760Kg\u003c\/p\u003e\n\u003cp\u003eMeasurements: 13X12X8\u003c\/p\u003e\n\u003cp\u003eLocator: B13P2C\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is for resale, the ST (Tax Substitution) value may apply. If the operation is subject to this tax, payment is the sole responsibility of the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":49757328048365,"sku":"WS4192","price":850.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/61175fe815c9b917c87255959b81ba2c.jpg?v=1775479963","url":"https:\/\/caboeletro.com\/en\/products\/disjuntor-tripolar-schneider-ng125h-16a-curva-c-380-415v-3p","provider":"Cabo Eletro","version":"1.0","type":"link"}