{"product_id":"disjuntor-tetrapolar-hager-mu-4-16e-c16-curva-c-16a-230v-6ka","title":"HAGER MU 4 16E Tetrapolar Circuit Breaker C16 Curve C 16A 230v 6kA","description":"\u003cp\u003eHAGER MU 4 16E C16 16A 230v 6kA Four-Pole Circuit Breaker Curve C\u003c\/p\u003e\n\u003cp\u003eNEW product out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: HAGER\u003c\/p\u003e\n\u003cp\u003eModel: MU 4 16E\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA four-pole circuit breaker is an electrical protection device designed to protect three-phase circuits with neutral.\u003c\/p\u003e\n\u003cp\u003eThe main function of a four-pole circuit breaker is to protect electrical circuits against overloads (excessive current) and short circuits. When it detects an anomalous current, the circuit breaker automatically trips, interrupting the flow of electricity and protecting the system from damage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe four-pole circuit breaker is an essential device for protecting three-phase circuits with neutral, common in large industrial and commercial installations. It simultaneously protects all three phases and the neutral, tripping in case of overload or short circuit, ensuring the safety of the electrical system and preventing damage to connected equipment.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNumber of protected poles\u003c\/p\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003cp\u003eNumber of poles\u003c\/p\u003e\n\u003cp\u003e4P\u003c\/p\u003e\n\u003cp\u003ePole type\u003c\/p\u003e\n\u003cp\u003e4P\u003c\/p\u003e\n\u003cp\u003eCurve\u003c\/p\u003e\n\u003cp\u003eC\u003c\/p\u003e\n\u003cp\u003eFunctions\u003c\/p\u003e\n\u003cp\u003eSimultaneously switching N-neutral\u003c\/p\u003e\n\u003cp\u003eNo\u003c\/p\u003e\n\u003cp\u003eConfiguration\u003c\/p\u003e\n\u003cp\u003eNumber of modules\u003c\/p\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003cp\u003eConnectivity\u003c\/p\u003e\n\u003cp\u003eUpper connection alignment for modular devices\u003c\/p\u003e\n\u003cp\u003eTerminal aligned\u003c\/p\u003e\n\u003cp\u003eLower connection alignment for modular devices\u003c\/p\u003e\n\u003cp\u003eTerminal aligned\u003c\/p\u003e\n\u003cp\u003eMain electrical characteristics\u003c\/p\u003e\n\u003cp\u003eRated short-circuit breaking capacity Icn AC according to IEC60898-1\u003c\/p\u003e\n\u003cp\u003e6 kA\u003c\/p\u003e\n\u003cp\u003eRated operating voltage Ue\u003c\/p\u003e\n\u003cp\u003e400V\u003c\/p\u003e\n\u003cp\u003ePower supply voltage type\u003c\/p\u003e\n\u003cp\u003eAC\u003c\/p\u003e\n\u003cp\u003eFrequency\u003c\/p\u003e\n\u003cp\u003e50\/60Hz\u003c\/p\u003e\n\u003cp\u003eVoltage\u003c\/p\u003e\n\u003cp\u003eRated insulation voltage\u003c\/p\u003e\n\u003cp\u003e500V\u003c\/p\u003e\n\u003cp\u003eRated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e4000V\u003c\/p\u003e\n\u003cp\u003eElectric current\u003c\/p\u003e\n\u003cp\u003eRated current\u003c\/p\u003e\n\u003cp\u003e16A\u003c\/p\u003e\n\u003cp\u003eRated service breaking capacity Ics AC according to IEC 60898-1\u003c\/p\u003e\n\u003cp\u003e6 kA\u003c\/p\u003e\n\u003cp\u003eMinimum\/maximum thermal operation limit value AC\u003c\/p\u003e\n\u003cp\u003e1.13 \/ 1.45 in.\u003c\/p\u003e\n\u003cp\u003eMagnetic regulating current\u003c\/p\u003e\n\u003cp\u003e5\/10 in.\u003c\/p\u003e\n\u003cp\u003eRated short-circuit breaking capacity Icn below 230 Vac according to IEC60898-1\u003c\/p\u003e\n\u003cp\u003e6 kA\u003c\/p\u003e\n\u003cp\u003eRated short-circuit breaking capacity Icn below 400 Vac according to IEC60898-1\u003c\/p\u003e\n\u003cp\u003e6 kA\u003c\/p\u003e\n\u003cp\u003eElectric current\/temperature\u003c\/p\u003e\n\u003cp\u003eRated current -25°C\u003c\/p\u003e\n\u003cp\u003e20.93A\u003c\/p\u003e\n\u003cp\u003eRated current -20°C\u003c\/p\u003e\n\u003cp\u003e20.53 A\u003c\/p\u003e\n\u003cp\u003eRated current -15°C\u003c\/p\u003e\n\u003cp\u003e20.12A\u003c\/p\u003e\n\u003cp\u003eRated current -10°C\u003c\/p\u003e\n\u003cp\u003e19.71A\u003c\/p\u003e\n\u003cp\u003eRated current -5°C\u003c\/p\u003e\n\u003cp\u003e19.28 A\u003c\/p\u003e\n\u003cp\u003eRated current 0°C\u003c\/p\u003e\n\u003cp\u003e18.85 A\u003c\/p\u003e\n\u003cp\u003eRated current 5°C\u003c\/p\u003e\n\u003cp\u003e18.4A\u003c\/p\u003e\n\u003cp\u003eRated current 10°C\u003c\/p\u003e\n\u003cp\u003e17.95A\u003c\/p\u003e\n\u003cp\u003eRated current 15°C\u003c\/p\u003e\n\u003cp\u003e17.48A\u003c\/p\u003e\n\u003cp\u003eRated current 20°C\u003c\/p\u003e\n\u003cp\u003e17A\u003c\/p\u003e\n\u003cp\u003eRated current 25°C\u003c\/p\u003e\n\u003cp\u003e16.51A\u003c\/p\u003e\n\u003cp\u003eRated current 30°C\u003c\/p\u003e\n\u003cp\u003e16A\u003c\/p\u003e\n\u003cp\u003eRated current 35°C\u003c\/p\u003e\n\u003cp\u003e15.47A\u003c\/p\u003e\n\u003cp\u003eRated current 40°C\u003c\/p\u003e\n\u003cp\u003e14.93A\u003c\/p\u003e\n\u003cp\u003eRated current 45°C\u003c\/p\u003e\n\u003cp\u003e14.37A\u003c\/p\u003e\n\u003cp\u003eRated current 50°C\u003c\/p\u003e\n\u003cp\u003e13.78A\u003c\/p\u003e\n\u003cp\u003eRated current 55°C\u003c\/p\u003e\n\u003cp\u003e13.16A\u003c\/p\u003e\n\u003cp\u003eRated current 60°C\u003c\/p\u003e\n\u003cp\u003e12.52 A\u003c\/p\u003e\n\u003cp\u003eRated current 65°C\u003c\/p\u003e\n\u003cp\u003e11.84A\u003c\/p\u003e\n\u003cp\u003eRated current 70°C\u003c\/p\u003e\n\u003cp\u003e11.12A\u003c\/p\u003e\n\u003cp\u003eCurrent correction factors\u003c\/p\u003e\n\u003cp\u003eRated current correction factor for 2 devices placed side by side\u003c\/p\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003cp\u003eRated current correction factor for 3 devices placed side by side\u003c\/p\u003e\n\u003cp\u003e0.95\u003c\/p\u003e\n\u003cp\u003eRated current correction factor for 4 and 5 devices placed side by side\u003c\/p\u003e\n\u003cp\u003e0.9\u003c\/p\u003e\n\u003cp\u003eRated current correction factor for 6 devices placed side by side\u003c\/p\u003e\n\u003cp\u003e0.85\u003c\/p\u003e\n\u003cp\u003eMagnetic trip correction factor at 100 Hz\u003c\/p\u003e\n\u003cp\u003e1.1\u003c\/p\u003e\n\u003cp\u003eMagnetic trip correction factor at 200 Hz\u003c\/p\u003e\n\u003cp\u003e1.2\u003c\/p\u003e\n\u003cp\u003eMagnetic trip correction factor at 400 Hz\u003c\/p\u003e\n\u003cp\u003e1.5\u003c\/p\u003e\n\u003cp\u003eMagnetic trip correction factor at 60 Hz\u003c\/p\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003cp\u003eDimensions\u003c\/p\u003e\n\u003cp\u003eInstalled product depth\u003c\/p\u003e\n\u003cp\u003e70mm\u003c\/p\u003e\n\u003cp\u003eInstalled product height\u003c\/p\u003e\n\u003cp\u003e83 millimeters\u003c\/p\u003e\n\u003cp\u003eInstalled product width\u003c\/p\u003e\n\u003cp\u003e70mm\u003c\/p\u003e\n\u003cp\u003eFrequency\u003c\/p\u003e\n\u003cp\u003eFrequency\u003c\/p\u003e\n\u003cp\u003e50 to 60Hz\u003c\/p\u003e\n\u003cp\u003ePower\u003c\/p\u003e\n\u003cp\u003eTotal power loss under IN\u003c\/p\u003e\n\u003cp\u003e8.74 W\u003c\/p\u003e\n\u003cp\u003ePower loss per pole in In\u003c\/p\u003e\n\u003cp\u003e2.22 W\u003c\/p\u003e\n\u003cp\u003eResistance\u003c\/p\u003e\n\u003cp\u003eElectrical resistance in number of cycles\u003c\/p\u003e\n\u003cp\u003e4000\u003c\/p\u003e\n\u003cp\u003eNumber of mechanical operations\u003c\/p\u003e\n\u003cp\u003e20,000\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 27\/08\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 0.336Kg\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10X15X24\u003c\/p\u003e\n\u003cp\u003eLocator: GP04CL122P03 B6P2B\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is for resale, the ST (Tax Substitution) value may apply. If the transaction is subject to this tax, the responsibility for payment lies solely with the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":49746931089645,"sku":"WS6324","price":150.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/1034c84c5c9a8924803cfff039d47afb.jpg?v=1775151824","url":"https:\/\/caboeletro.com\/en\/products\/disjuntor-tetrapolar-hager-mu-4-16e-c16-curva-c-16a-230v-6ka","provider":"Cabo Eletro","version":"1.0","type":"link"}