{"product_id":"disjuntor-schneider-nsx100n-tm-3p3t-100a-690v-60hz","title":"Circuit Breaker Schneider NSX100N-TM-3P3T 100A 690V 60Hz","description":"\u003cp\u003eSchneider NSX100-N-TM-3P3T LV429840 70-100A 690V 60Hz Circuit Breaker\u003c\/p\u003e\n\u003cp\u003eNew product, out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: Schneider\u003c\/p\u003e\n\u003cp\u003eModel: NSX100-N-TM-3P3T GCR-NSX100-630 LV429840 \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA circuit breaker is a protective device used in electrical systems to interrupt the flow of electrical current in situations of overload, short circuit, or other abnormal conditions. It is designed to protect electrical circuits and connected equipment from damage caused by excessive currents.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe NSX100-N-TM-3P3T model is a specific type of circuit breaker. Let's analyze its characteristics in detail:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e1. Rated Interrupting Capacity: The value 100 indicates that the circuit breaker is capable of safely interrupting currents up to 100 amperes. This means it can handle currents within this range without causing damage to equipment or fire hazards.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e2. Construction Type: The \"N\" indicates that the circuit breaker is of the molded case type, which is one of the most common technologies for low voltage circuit breakers. The molded case is a solid, insulated structure that houses the internal components of the circuit breaker, providing safety and protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e3. Configuration: The \"TM\" indicates that the circuit breaker is of the thermal-magnetic type, which means it has combined thermal and magnetic protection elements in its operation. The thermal element monitors current over time, while the magnetic element responds quickly to short-circuit currents.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e4. Number of Poles: The \"3P3T\" indicates that the circuit breaker has 3 poles (three phases) and 3 operating positions (three switching positions). The poles represent the electrical connections for each phase of a three-phase system. Each switching position can represent different configurations, such as on, off, or tripped (actuated after detecting an abnormal condition).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn addition to these specifications, circuit breakers generally have other features, such as rated current adjustment, protection sensitivity adjustment, visual indication of the circuit breaker's status (on\/off), coordination capability with other protective devices, among others.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003cp\u003eCompact\u003c\/p\u003e\n\u003cp\u003eProduct Name\u003c\/p\u003e\n\u003cp\u003eComPact NSX\u003c\/p\u003e\n\u003cp\u003eProduct line\u003c\/p\u003e\n\u003cp\u003eComPact NSX100...250\u003c\/p\u003e\n\u003cp\u003eDevice short name\u003c\/p\u003e\n\u003cp\u003eNSX100N\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eCircuit breaker\u003c\/p\u003e\n\u003cp\u003eDevice application\u003c\/p\u003e\n\u003cp\u003eDistribution\u003c\/p\u003e\n\u003cp\u003eNumber of poles\u003c\/p\u003e\n\u003cp\u003e3P\u003c\/p\u003e\n\u003cp\u003eDescription of protected poles\u003c\/p\u003e\n\u003cp\u003e3t\u003c\/p\u003e\n\u003cp\u003e[In] rated current\u003c\/p\u003e\n\u003cp\u003e100 A at 40 °C\u003c\/p\u003e\n\u003cp\u003e[Ue] rated operational voltage\u003c\/p\u003e\n\u003cp\u003e690 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eNetwork type\u003c\/p\u003e\n\u003cp\u003eAC\u003c\/p\u003e\n\u003cp\u003eNetwork frequency\u003c\/p\u003e\n\u003cp\u003e50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eSuitability for isolation\u003c\/p\u003e\n\u003cp\u003eYes conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eUtilisation category\u003c\/p\u003e\n\u003cp\u003eCategory A\u003c\/p\u003e\n\u003cp\u003e[Icu] rated ultimate short-circuit breaking capacity\u003c\/p\u003e\n\u003cp\u003e85 kA at 240 V AC 50\/60 Hz conforming to UL 508\u003c\/p\u003e\n\u003cp\u003e10 kA Icu at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e35 kA Icu at 525 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e20 kA at 600 V AC 50\/60 Hz conforming to UL 508\u003c\/p\u003e\n\u003cp\u003e50 kA at 480 V AC 50\/60 Hz conforming to UL 508\u003c\/p\u003e\n\u003cp\u003e36 kA Icu at 500 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e50 kA Icu at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e50 kA Icu at 440 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e90 kA Icu at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003ePerformance level\u003c\/p\u003e\n\u003cp\u003eN 50 kA 415 V AC\u003c\/p\u003e\n\u003cp\u003eTrip unit name\u003c\/p\u003e\n\u003cp\u003eTM-D\u003c\/p\u003e\n\u003cp\u003eTrip unit technology\u003c\/p\u003e\n\u003cp\u003eThermal-magnetic\u003c\/p\u003e\n\u003cp\u003eTrip unit protection functions\u003c\/p\u003e\n\u003cp\u003eLI\u003c\/p\u003e\n\u003cp\u003eControl type\u003c\/p\u003e\n\u003cp\u003eToggle\u003c\/p\u003e\n\u003cp\u003eCircuit breaker mounting mode\u003c\/p\u003e\n\u003cp\u003eFixed\u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e800 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e8 kV\u003c\/p\u003e\n\u003cp\u003e[Ics] rated service short-circuit breaking capacity\u003c\/p\u003e\n\u003cp\u003e10 kA at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e35 kA at 525 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e36 kA at 500 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e50 kA at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e50 kA at 440 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e90 kA at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eMechanical durability\u003c\/p\u003e\n\u003cp\u003e50000 cycles\u003c\/p\u003e\n\u003cp\u003eElectrical durability\u003c\/p\u003e\n\u003cp\u003e10000 cycles at 690 V In\u003c\/p\u003e\n\u003cp\u003e20000 cycles at 690 V In\/2\u003c\/p\u003e\n\u003cp\u003e30000 cycles at 440 V In\/\u003c\/p\u003e\n\u003cp\u003e50000 cycles at 440 V In\/2\u003c\/p\u003e\n\u003cp\u003eMounting support\u003c\/p\u003e\n\u003cp\u003eBackplate\u003c\/p\u003e\n\u003cp\u003eUpstream connection\u003c\/p\u003e\n\u003cp\u003eFront\u003c\/p\u003e\n\u003cp\u003eDownstream connection\u003c\/p\u003e\n\u003cp\u003eFront\u003c\/p\u003e\n\u003cp\u003eConnection pitch\u003c\/p\u003e\n\u003cp\u003e35 mm\u003c\/p\u003e\n\u003cp\u003eProtection type\u003c\/p\u003e\n\u003cp\u003eL: for overload protection (thermal)\u003c\/p\u003e\n\u003cp\u003eI: for short-circuit protection (magnetic)\u003c\/p\u003e\n\u003cp\u003eTrip unit rating\u003c\/p\u003e\n\u003cp\u003e100 A at 40 °C\u003c\/p\u003e\n\u003cp\u003eLong-time protection pick-up adjustment type Ir (thermal protection)\u003c\/p\u003e\n\u003cp\u003eAdjustable\u003c\/p\u003e\n\u003cp\u003e[Ir] long-time protection pick-up adjustment range\u003c\/p\u003e\n\u003cp\u003e0.7...1 x In\u003c\/p\u003e\n\u003cp\u003eLong-time protection delay adjustment type tr\u003c\/p\u003e\n\u003cp\u003eFixed\u003c\/p\u003e\n\u003cp\u003e[tr] long-time protection delay adjustment range\u003c\/p\u003e\n\u003cp\u003e120…400 s at 1.5 x In\u003c\/p\u003e\n\u003cp\u003e15 s at 6 x Ir\u003c\/p\u003e\n\u003cp\u003eShort-time protection pick-up adjustment type Isd\u003c\/p\u003e\n\u003cp\u003eFixed\u003c\/p\u003e\n\u003cp\u003e[Isd] short-time protection pick-up adjustment range\u003c\/p\u003e\n\u003cp\u003e800 A\u003c\/p\u003e\n\u003cp\u003eShort-time protection delay adjustment type tsd\u003c\/p\u003e\n\u003cp\u003eFixed\u003c\/p\u003e\n\u003cp\u003eEarth-leakage protection\u003c\/p\u003e\n\u003cp\u003eNo\u003c\/p\u003e\n\u003cp\u003eNumber of slots for electrical auxiliaries\u003c\/p\u003e\n\u003cp\u003e5 slots\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 05\/15\/2023\u003c\/p\u003e\n\u003cp\u003eWeight: 1,000\u003c\/p\u003e\n\u003cp\u003eMeasurements: 18x9x7\u003c\/p\u003e\n\u003cp\u003eLocator: B2P2B\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ST (Tax Substitution) value may apply. If the operation is subject to this tax, payment is the sole responsibility of the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial ltda thanks you\u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":49757856399597,"sku":"WS69","price":1000.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/f56bed6144f95a9dc773fb1777dce10a.jpg?v=1775502187","url":"https:\/\/caboeletro.com\/en\/products\/disjuntor-schneider-nsx100n-tm-3p3t-100a-690v-60hz","provider":"Cabo Eletro","version":"1.0","type":"link"}