{"product_id":"disjuntor-schneider-masterpact-nw08h1-800a-1000v-12ka-3p","title":"Circuit Breaker Schneider Masterpact NW08H1 800A 1000V 12kA 3P","description":"\u003cp\u003eSchneider Masterpact NW08H1 Circuit Breaker 800A 1000V 12kA 3P\u003c\/p\u003e\n\u003cp\u003eNew product out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: Schneider Masterpact\u003c\/p\u003e\n\u003cp\u003eModel: NW08H1\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA circuit breaker is a protective device used in electrical installations to automatically interrupt the flow of electrical current in the event of an overload, short circuit, or system failure. Its primary function is to protect electrical circuits, equipment, and people from damage caused by abnormal electrical conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn situations where the electrical current exceeds the nominal value for a prolonged period, the circuit breaker trips to prevent wires and equipment from being damaged by the heat generated by the overload.\u003c\/p\u003e\n\u003cp\u003eShort-Circuit Protection:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWhen a short circuit occurs, the circuit breaker trips quickly to interrupt the current flow, preventing more severe damage, such as fires.\u003c\/p\u003e\n\u003cp\u003eEase of Reset:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUnlike fuses, which need to be replaced after a fault, the circuit breaker can be manually reset after the problem is corrected.\u003c\/p\u003e\n\u003cp\u003eCircuit Isolation:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe circuit breaker can also be used to manually switch off a circuit during maintenance or installation of new components.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cp\u003eResidential Installations:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection of lighting circuits, outlets, and electrical appliances.\u003c\/p\u003e\n\u003cp\u003eCommercial and Industrial Installations:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtection of equipment, machinery, and power systems.\u003c\/p\u003e\n\u003cp\u003ePower Distribution Systems:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHigh-voltage circuit breakers protect distribution networks and substations from serious faults.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMasterpact NW08H1 Circuit Breaker - 800 A - 3 poles - draw-out - without trip unit\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003cp\u003eMasterpact\u003c\/p\u003e\n\u003cp\u003eProduct name\u003c\/p\u003e\n\u003cp\u003eMasterpact NW\u003c\/p\u003e\n\u003cp\u003eCircuit breaker name\u003c\/p\u003e\n\u003cp\u003eMasterPact NW08H1\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eCircuit breaker\u003c\/p\u003e\n\u003cp\u003eDevice application\u003c\/p\u003e\n\u003cp\u003ePower distribution protection\u003c\/p\u003e\n\u003cp\u003ePoles description\u003c\/p\u003e\n\u003cp\u003e3P\u003c\/p\u003e\n\u003cp\u003eControl unit\u003c\/p\u003e\n\u003cp\u003eWithout control unit\u003c\/p\u003e\n\u003cp\u003e[In] rated current\u003c\/p\u003e\n\u003cp\u003e800 A at 40 °C\u003c\/p\u003e\n\u003cp\u003ePerformance type\u003c\/p\u003e\n\u003cp\u003eH1 65 kA 440 V AC\u003c\/p\u003e\n\u003cp\u003e[Ue] rated operational voltage\u003c\/p\u003e\n\u003cp\u003e690 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eSuitability for isolation\u003c\/p\u003e\n\u003cp\u003eYes conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eSelectivity category\u003c\/p\u003e\n\u003cp\u003eCategory B\u003c\/p\u003e\n\u003cp\u003eControl type\u003c\/p\u003e\n\u003cp\u003eNon-illuminated button\u003c\/p\u003e\n\u003cp\u003eMounting mode\u003c\/p\u003e\n\u003cp\u003eDraw-out\u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003e[Icu] rated ultimate short-circuit breaking capacity\u003c\/p\u003e\n\u003cp\u003e65 kA at 220\/415 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e65 kA at 440 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e65 kA at 525 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e65 kA at 690 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e[Ics] rated service short-circuit breaking capacity\u003c\/p\u003e\n\u003cp\u003e65 kA at 220\/415 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e65 kA at 440 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e65 kA at 525 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e65 kA at 690 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e[Icw] rated short-time withstand current\u003c\/p\u003e\n\u003cp\u003e65 kA 1 s\u003c\/p\u003e\n\u003cp\u003e36 kA 3 s\u003c\/p\u003e\n\u003cp\u003e[Icm] rated short-circuit making capacity\u003c\/p\u003e\n\u003cp\u003e143 kA 220\/415 V AC at 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e143 kA 440 V AC at 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e143 kA 525 V AC at 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e143 kA 690 V AC at 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eSensor rating\u003c\/p\u003e\n\u003cp\u003e400 A\u003c\/p\u003e\n\u003cp\u003e800 A\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e1000 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e12 kV\u003c\/p\u003e\n\u003cp\u003ePower dissipation in W\u003c\/p\u003e\n\u003cp\u003e100 W\u003c\/p\u003e\n\u003cp\u003eMaximum breaking time\u003c\/p\u003e\n\u003cp\u003e25 ms\u003c\/p\u003e\n\u003cp\u003eClosing time\u003c\/p\u003e\n\u003cp\u003e70 ms\u003c\/p\u003e\n\u003cp\u003eMounting support\u003c\/p\u003e\n\u003cp\u003eBackplate\u003c\/p\u003e\n\u003cp\u003eRails\u003c\/p\u003e\n\u003cp\u003eUpper connections\u003c\/p\u003e\n\u003cp\u003eFront\u003c\/p\u003e\n\u003cp\u003eRear\u003c\/p\u003e\n\u003cp\u003eLower connection\u003c\/p\u003e\n\u003cp\u003eFront\u003c\/p\u003e\n\u003cp\u003eRear\u003c\/p\u003e\n\u003cp\u003eConnection pitch\u003c\/p\u003e\n\u003cp\u003e115 mm\u003c\/p\u003e\n\u003cp\u003eMechanical durability\u003c\/p\u003e\n\u003cp\u003e12500 cycles without maintenance\u003c\/p\u003e\n\u003cp\u003e25000 cycles with maintenance\u003c\/p\u003e\n\u003cp\u003eElectrical durability\u003c\/p\u003e\n\u003cp\u003e10000 cycles 440 V AC 50\/60 Hz without maintenance conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e10000 cycles 690 V AC 50\/60 Hz without maintenance conforming to EN\/IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eAC -23A: 10000 cycles 440 V AC 50\/60 Hz without maintenance conforming to EN\/IEC 60947-3\u003c\/p\u003e\n\u003cp\u003eAC -23A: 10000 cycles 690 V AC 50\/60 Hz without maintenance conforming to EN\/IEC 60947-3\u003c\/p\u003e\n\u003cp\u003eAC-3: 6000 cycles 440\/690 V AC 50\/60 Hz without maintenance conforming to EN\/IEC 60947-3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 08\/23\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 56.000KG\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10x15x24\u003c\/p\u003e\n\u003cp\u003eLocator: A11P4A\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is for resale, the ICMS-ST (Tax Substitution) value may apply. If the operation is subject to this tax, payment is the exclusive responsibility of the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e----------------------------- ATTENTION ------------------------------\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNew material, never used but with stock marks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCheck photos to verify the condition of the items that will be delivered after purchase.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e---------------------------------------------------------------------------------------------------\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":49746888622317,"sku":"WS6689","price":15850.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/66fbef1b5a90add3c75d83680352cbd5.jpg?v=1775149304","url":"https:\/\/caboeletro.com\/en\/products\/disjuntor-schneider-masterpact-nw08h1-800a-1000v-12ka-3p","provider":"Cabo Eletro","version":"1.0","type":"link"}