{"product_id":"disjuntor-motor-telemecanique-gv2-p14-6-10a","title":"Motor Starter Telemecanique GV2-P14 6-10A","description":"\u003cp\u003eTelemecanique GV2-P14 6-10A Motor Circuit Breaker\u003c\/p\u003e\n\u003cp\u003eUsed product, out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: Telemecanique\u003c\/p\u003e\n\u003cp\u003eModel: GV2-P14\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA motor circuit breaker is an electrical protection device designed to protect electric motors against common faults such as overload, short-circuit, and phase loss. It combines the functions of a circuit breaker and a thermal relay, ensuring an integrated and efficient solution for motor safety.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHow it works?\u003c\/p\u003e\n\u003cp\u003eOverload Protection (Thermal):\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA bimetallic element in the circuit breaker heats up when the motor draws current above its nominal limit for a prolonged period.\u003c\/p\u003e\n\u003cp\u003eThis heating causes the element to deform and trigger the circuit shutdown.\u003c\/p\u003e\n\u003cp\u003eShort-Circuit Protection (Magnetic):\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA magnetic coil detects abrupt current increases caused by short-circuits.\u003c\/p\u003e\n\u003cp\u003eWhen the peak is detected, the circuit breaker trips instantly.\u003c\/p\u003e\n\u003cp\u003ePhase Loss Protection:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn three-phase motors, the loss of one phase causes a current imbalance. The circuit breaker detects this fault and shuts down the motor to prevent damage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA motor circuit breaker is an electrical protection device designed to protect electric motors against common faults such as overload, short-circuit, and phase loss. It combines the functions of a circuit breaker and a thermal relay, ensuring an integrated and efficient solution for motor safety.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHow it works?\u003c\/p\u003e\n\u003cp\u003eOverload Protection (Thermal):\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA bimetallic element in the circuit breaker heats up when the motor draws current beyond its nominal limit for a prolonged period.\u003c\/p\u003e\n\u003cp\u003eThis heating causes the element to deform and trigger the circuit shutdown.\u003c\/p\u003e\n\u003cp\u003eShort-Circuit Protection (Magnetic):\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA magnetic coil detects abrupt current increases caused by short-circuits.\u003c\/p\u003e\n\u003cp\u003eWhen the peak is detected, the circuit breaker trips instantly.\u003c\/p\u003e\n\u003cp\u003ePhase Loss Protection:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn three-phase motors, the loss of one phase causes a current imbalance. The circuit breaker detects this fault and shuts down the motor to prevent damage.\u003c\/p\u003e\n\u003cp\u003eMain Features:\u003c\/p\u003e\n\u003cp\u003eCurrent Adjustment:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAllows setting the current limit according to motor specifications.\u003c\/p\u003e\n\u003cp\u003eAutomatic Trip:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProtects against faults without the need for immediate manual intervention.\u003c\/p\u003e\n\u003cp\u003eManual Reset:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAfter tripping, it can be manually reclosed to restore operation.\u003c\/p\u003e\n\u003cp\u003eCompatible with Three-Phase and Single-Phase Motors:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUsed in systems of different voltages and powers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cp\u003eIndustries:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMachines with electric motors, such as compressors, pumps, and conveyor belts.\u003c\/p\u003e\n\u003cp\u003eAutomation Systems:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMotor protection in automatically controlled systems.\u003c\/p\u003e\n\u003cp\u003eAgribusiness:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWater pumps and irrigation motors.\u003c\/p\u003e\n\u003cp\u003eCommercial Infrastructures:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eVentilation and air conditioning systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTesys Deca 6-10A thermal-magnetic motor circuit breaker with rotary knob\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe new generations of TeSys Deca motor circuit breakers - frame 2 offer a complete solution for almost all applications. It provides short-circuit protection, overload protection, and motor control (ON\/OFF). This product has 3 poles, a capacity of 6-10A\/690V, and is intended for 3-4kW\/400V three-phase motor applications. It provides thermal-magnetic protection with a thermal adjustment range of 6-10A, magnetic trip at 9xIn, and high breaking capacity Icu 100kA@400V. In addition, it features IP20 protection and screw terminal connection. It also allows start\/stop control via a rotary knob guaranteed for 100,000 AC-3 cycles. This product is multi-standard certified (IEC, UL, CSA, CCC, EAC, Marine). Tesys Deca motor circuit breakers carry the Green PremiumTM label, which promises compliance with the latest regulations, transparency in environmental impacts, circular, and low CO2 products.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003erange\u003c\/p\u003e\n\u003cp\u003eTeSys Deca\u003c\/p\u003e\n\u003cp\u003eProduct name\u003c\/p\u003e\n\u003cp\u003eTeSys GV2\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eMotor circuit breaker\u003c\/p\u003e\n\u003cp\u003eDevice short name\u003c\/p\u003e\n\u003cp\u003eGV2P\u003c\/p\u003e\n\u003cp\u003eDevice application\u003c\/p\u003e\n\u003cp\u003eMotor protection\u003c\/p\u003e\n\u003cp\u003eTripping unit technology\u003c\/p\u003e\n\u003cp\u003eThermal-magnetic\u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003ePoles description\u003c\/p\u003e\n\u003cp\u003e3P\u003c\/p\u003e\n\u003cp\u003eNetwork type\u003c\/p\u003e\n\u003cp\u003eAC\u003c\/p\u003e\n\u003cp\u003eUtilisation category\u003c\/p\u003e\n\u003cp\u003eCategory A conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eAC-3 conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eAC-3e conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eNetwork frequency\u003c\/p\u003e\n\u003cp\u003e50\/60 Hz conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eMotor power kW\u003c\/p\u003e\n\u003cp\u003e3 kW at 400\/415 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e5 kW at 500 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e5.5 kW at 690 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eBreaking capacity\u003c\/p\u003e\n\u003cp\u003e100 kA Icu at 230\/240 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 kA Icu at 400\/415 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 kA Icu at 440 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e50 kA Icu at 500 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e6 kA Icu at 690 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e[Ics] rated service short-circuit breaking capacity\u003c\/p\u003e\n\u003cp\u003e100 % at 230\/240 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 % at 400\/415 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 % at 440 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 % at 500 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 % at 690 V AC 50\/60 Hz for IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eControl type\u003c\/p\u003e\n\u003cp\u003eRotary handle\u003c\/p\u003e\n\u003cp\u003e[In] rated current\u003c\/p\u003e\n\u003cp\u003e10 A\u003c\/p\u003e\n\u003cp\u003eThermal protection adjustment range\u003c\/p\u003e\n\u003cp\u003e6…10 A conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eMagnetic tripping current\u003c\/p\u003e\n\u003cp\u003e149 A\u003c\/p\u003e\n\u003cp\u003e[Ith] conventional free-air thermal current\u003c\/p\u003e\n\u003cp\u003e10 A conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003e[Ue] rated operational voltage\u003c\/p\u003e\n\u003cp\u003e690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e6 kV IEC 60947-2\u003c\/p\u003e\n\u003cp\u003ePhase failure sensitivity\u003c\/p\u003e\n\u003cp\u003eYes conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eSuitability for isolation\u003c\/p\u003e\n\u003cp\u003eYes conforming to IEC 60947-1\u003c\/p\u003e\n\u003cp\u003ePower dissipation per pole\u003c\/p\u003e\n\u003cp\u003e2.5 W\u003c\/p\u003e\n\u003cp\u003eMechanical durability\u003c\/p\u003e\n\u003cp\u003e100000 cycles\u003c\/p\u003e\n\u003cp\u003eElectrical durability\u003c\/p\u003e\n\u003cp\u003e100000 cycles of AC-3 at 415 V pol\u003c\/p\u003e\n\u003cp\u003e100000 cycles of AC-3e at 415 V pol\u003c\/p\u003e\n\u003cp\u003eRated duty\u003c\/p\u003e\n\u003cp\u003eContinuous conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eTightening torque\u003c\/p\u003e\n\u003cp\u003e1.7 N.m - on screw connection\u003c\/p\u003e\n\u003cp\u003eMounting mode\u003c\/p\u003e\n\u003cp\u003e35mm DIN rail: clip-on\u003c\/p\u003e\n\u003cp\u003ePanel: screw-mounted (with 2 x M4 screws)\u003c\/p\u003e\n\u003cp\u003eMounting position\u003c\/p\u003e\n\u003cp\u003eHorizontal\u003c\/p\u003e\n\u003cp\u003eVertical\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 03\/12\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 0.320g\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10x15x24\u003c\/p\u003e\n\u003cp\u003eLocator: A13P2B\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ICMS-ST (Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment lies exclusively with the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you\u003c\/p\u003e","brand":"TELEMECANIQUE","offers":[{"title":"Default Title","offer_id":49744150790381,"sku":"WS7353","price":110.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/290797b90b3250a98fc8d8792f8bc96a.jpg?v=1775070985","url":"https:\/\/caboeletro.com\/en\/products\/disjuntor-motor-telemecanique-gv2-p14-6-10a","provider":"Cabo Eletro","version":"1.0","type":"link"}