{"product_id":"disjuntor-motor-telemecanique-gv2-p08-2-5-4a","title":"Motor Breaker Telemecanique GV2-P08 2.5-4A","description":"\u003cp\u003eTelemecanique GV2-P08 2.5-4A Motor Circuit Breaker\u003c\/p\u003e\n\u003cp\u003eNEW product out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: Telemecanique\u003c\/p\u003e\n\u003cp\u003eModel: GV2-P08\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA motor circuit breaker is a protection device used to protect electric motors against overloads, short circuits and, in some cases, phase loss. It combines the functions of a conventional circuit breaker with specific thermal and magnetic protection characteristics tailored to the needs of electric motors.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain functions of the motor circuit breaker:\u003c\/p\u003e\n\u003cp\u003eOverload protection:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThermal protection is adjustable and prevents the motor from operating above its rated current for an extended period, preventing overheating and damage.\u003c\/p\u003e\n\u003cp\u003eShort-circuit protection:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMagnetic protection trips the circuit immediately upon detecting a short circuit, preventing serious damage to the motor and the system.\u003c\/p\u003e\n\u003cp\u003ePhase loss protection (in three-phase motors):\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSome models detect the absence of an electrical phase, protecting the motor against improper operation, which can cause overheating.\u003c\/p\u003e\n\u003cp\u003eSwitching function:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIt can be used as a switching device, turning the motor on and off manually.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTeSys Deca 2.5-4A thermomagnetic motor circuit breaker rotary handle\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe new generations of TeSys Deca motor circuit breakers - frame 2 offer a complete solution for almost all applications. It provides short-circuit protection, overload protection and motor control (ON\/OFF). This product has 3 poles, 2.5-4A\/690V capacity and is intended for 1.1-1.5kW\/400V three-phase motor applications. It provides thermomagnetic protection with a thermal adjustment range of 2.5-4A, magnetic tripping at 9xIn and high breaking capacity Icu 100kA@400V. In addition, it has IP20 protection and screw terminal connection. It also allows start\/stop control by rotary handle guaranteed for 100,000 AC-3 cycles. This product has multi-standard certification (IEC, UL, CSA, CCC, EAC, Marine). TeSys Deca motor circuit breakers carry the Green PremiumTM label, which promises compliance with the latest regulations, transparency in environmental impacts, circular and low CO2 products.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain\u003c\/p\u003e\n\u003cp\u003erange\u003c\/p\u003e\n\u003cp\u003eTeSys Deca\u003c\/p\u003e\n\u003cp\u003eProduct name\u003c\/p\u003e\n\u003cp\u003eTeSys GV2\u003c\/p\u003e\n\u003cp\u003eProduct or component type\u003c\/p\u003e\n\u003cp\u003eMotor circuit breaker\u003c\/p\u003e\n\u003cp\u003eDevice short name\u003c\/p\u003e\n\u003cp\u003eGV2P\u003c\/p\u003e\n\u003cp\u003eDevice application\u003c\/p\u003e\n\u003cp\u003eMotor protection\u003c\/p\u003e\n\u003cp\u003etripping unit technology\u003c\/p\u003e\n\u003cp\u003eThermomagnetic\u003c\/p\u003e\n\u003cp\u003eComplementary\u003c\/p\u003e\n\u003cp\u003ePoles description\u003c\/p\u003e\n\u003cp\u003e3P\u003c\/p\u003e\n\u003cp\u003eNetwork type\u003c\/p\u003e\n\u003cp\u003eAC\u003c\/p\u003e\n\u003cp\u003eUtilisation category\u003c\/p\u003e\n\u003cp\u003eCategory A conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eAC-3 conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eAC-3e conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eNetwork frequency\u003c\/p\u003e\n\u003cp\u003e50\/60 Hz conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eMotor power kW\u003c\/p\u003e\n\u003cp\u003e1.1 kW at 400\/415 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e1.5 kW at 500 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e2.2 kW at 690 V AC 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eBreaking capacity\u003c\/p\u003e\n\u003cp\u003e100 kA Icu at 230\/240 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 kA Icu at 400\/415 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 kA Icu at 440 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 kA Icu at 500 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e8 kA Icu at 690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e[Ics] rated service short-circuit breaking capacity\u003c\/p\u003e\n\u003cp\u003e100 % at 230\/240 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 % at 400\/415 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 % at 440 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 % at 500 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e100 % at 690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003eControl type\u003c\/p\u003e\n\u003cp\u003eRotary handle\u003c\/p\u003e\n\u003cp\u003e[In] rated current\u003c\/p\u003e\n\u003cp\u003e4 A\u003c\/p\u003e\n\u003cp\u003eThermal protection adjustment range\u003c\/p\u003e\n\u003cp\u003e2.5…4 A conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eMagnetic tripping current\u003c\/p\u003e\n\u003cp\u003e74 A\u003c\/p\u003e\n\u003cp\u003e[Ith] conventional free air thermal current\u003c\/p\u003e\n\u003cp\u003e4 A conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003e[Ue] rated operational voltage\u003c\/p\u003e\n\u003cp\u003e690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e[Ui] rated insulation voltage\u003c\/p\u003e\n\u003cp\u003e690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/p\u003e\n\u003cp\u003e[Uimp] rated impulse withstand voltage\u003c\/p\u003e\n\u003cp\u003e6 kV IEC 60947-2\u003c\/p\u003e\n\u003cp\u003ePhase failure sensitivity\u003c\/p\u003e\n\u003cp\u003eYes conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eSuitability for isolation\u003c\/p\u003e\n\u003cp\u003eYes conforming to IEC 60947-1\u003c\/p\u003e\n\u003cp\u003ePower dissipation per pole\u003c\/p\u003e\n\u003cp\u003e2.5 W\u003c\/p\u003e\n\u003cp\u003eMechanical durability\u003c\/p\u003e\n\u003cp\u003e100000 cycles\u003c\/p\u003e\n\u003cp\u003eElectrical durability\u003c\/p\u003e\n\u003cp\u003e100000 cycles of AC-3 at 415 V pole\u003c\/p\u003e\n\u003cp\u003e100000 cycles of AC-3e at 415 V pole\u003c\/p\u003e\n\u003cp\u003eRated load\u003c\/p\u003e\n\u003cp\u003eContinuous conforming to IEC 60947-4-1\u003c\/p\u003e\n\u003cp\u003eTightening torque\u003c\/p\u003e\n\u003cp\u003e1.7 N.m - on screw terminals\u003c\/p\u003e\n\u003cp\u003eFixing mode\u003c\/p\u003e\n\u003cp\u003e35mm DIN rail: clip-on\u003c\/p\u003e\n\u003cp\u003ePanel: screw-fixed (with 2 x M4 screws)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 02\/12\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 0.344Kg\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10x15x24\u003c\/p\u003e\n\u003cp\u003eLocator: A21P3A\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ST (Tax Substitution) value may be applied. If the operation is subject to this tax, the responsibility for payment is solely that of the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e","brand":"Telemecanique","offers":[{"title":"Default Title","offer_id":47500344295661,"sku":"WS7366","price":180.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/f409e9dea93bbbddc2d04a27442602f0.jpg?v=1733925008","url":"https:\/\/caboeletro.com\/en\/products\/disjuntor-motor-telemecanique-gv2-p08-2-5-4a","provider":"Cabo Eletro","version":"1.0","type":"link"}