{"product_id":"detector-de-falha-de-isolamento-schneider-1518384v2","title":"Schneider Insulation Fault Detector 1518384V2","description":"\u003cp\u003eSchneider 1518384V2 220-240VAC Insulation Fault Detector\u003c\/p\u003e\n\u003cp\u003eNew product out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: Schneider\u003c\/p\u003e\n\u003cp\u003eModel: 1518384V2 220-240VAC\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eAn insulation fault detector is a device used to monitor and detect the presence of insulation faults in electrical systems. These faults can occur when there is a malfunction or deterioration of the electrical insulation between electrical conductors or between a conductor and the ground.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe main function of an insulation fault detector is to identify any current leakage that may occur due to an insulation fault, which can pose a safety risk or cause damage to electrical equipment. When an insulation fault is detected, the detector can trigger an alarm, shut down the circuit, or activate other safety devices to prevent more serious consequences, such as fires, electric shocks, or equipment damage.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eInsulation fault detectors typically work by measuring the resistance between the conductors and the ground. If the resistance drops below a certain predefined limit, it indicates the presence of an insulation fault. Some insulation fault detectors can also monitor leakage current in the circuit and trigger an alarm or shutdown if it exceeds a specified value.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eThe Schneider 1518384V2 Insulation Fault Detector is a crucial safety device for protecting\u003c\/p\u003e\n\u003cp\u003eelectrical installations against the risk of insulation faults. Its main function is to detect and indicate the presence\u003c\/p\u003e\n\u003cp\u003eof dangerous leakage currents, ensuring the safety of people and equipment.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eFeatures:\u003c\/p\u003e\n\u003cp\u003eRated voltage: 220-240 VAC\u003c\/p\u003e\n\u003cp\u003eRated frequency: 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eRated current: 32 A\u003c\/p\u003e\n\u003cp\u003eSensitivity: 30 mA\u003c\/p\u003e\n\u003cp\u003eResponse time: \u0026lt; 0.5 s\u003c\/p\u003e\n\u003cp\u003eReset type: Manual\u003c\/p\u003e\n\u003cp\u003eFault indication: Red LED\u003c\/p\u003e\n\u003cp\u003eOperating temperature: -5 °C to 40 °C\u003c\/p\u003e\n\u003cp\u003eProtection degree: IP20\u003c\/p\u003e\n\u003cp\u003eApplicable standard: IEC 61557\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eFunctionalities:\u003c\/p\u003e\n\u003cp\u003eInsulation fault detection: The detector continuously monitors the current flowing through the protected circuit. If it detects a leakage current greater than the rated value (30 mA), the device automatically shuts down the circuit, preventing the risk of electric shock.\u003c\/p\u003e\n\u003cp\u003eVisual fault indication: A red LED on the front panel of the detector lights up to indicate the presence of an insulation fault. This makes it easy to identify the problem and take corrective action.\u003c\/p\u003e\n\u003cp\u003eManual reset: The detector has a manual reset button that must be pressed to re-energize the circuit after the insulation fault has been corrected. This ensures that the circuit is not accidentally re-energized while the fault persists.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eBenefits:\u003c\/p\u003e\n\u003cp\u003eEnhanced safety: The insulation fault detector protects people and equipment from the risk of electric shocks caused by insulation faults.\u003c\/p\u003e\n\u003cp\u003eFire prevention: Quick detection and shutdown of current in case of an insulation fault can help prevent electrical fires.\u003c\/p\u003e\n\u003cp\u003eGreater reliability: The detector ensures the continuous and safe operation of the electrical installation.\u003c\/p\u003e\n\u003cp\u003eEasy installation: The device is compact and easy to install in any electrical panel.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cp\u003eThe Schneider 1518384V2 insulation fault detector is ideal for use in various residential, commercial, and industrial applications, such as:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eResidential electrical installations: houses, apartments, condominiums.\u003c\/p\u003e\n\u003cp\u003eCommercial electrical installations: offices, stores, restaurants.\u003c\/p\u003e\n\u003cp\u003eIndustrial electrical installations: factories, power plants, warehouses.\u003c\/p\u003e\n\u003cp\u003eElectrical equipment: machinery, tools, home appliances.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eDate: 09\/04\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 0.300\u003c\/p\u003e\n\u003cp\u003eMeasurements: 10x15x24\u003c\/p\u003e\n\u003cp\u003eLocator: A10P2C\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is intended for resale, the ST (Substituição Tributária - Tax Substitution) value may apply.\u003c\/p\u003e\n\u003cp\u003eIf the operation is subject to this tax, the responsibility for payment lies solely with the buyer.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e------------------------ ATTENTION --------------------------------\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eNew material, never used but with stock marks.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eConsult photos to check the condition of the items that will be delivered after purchase.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e---------------------------------------------------------------------\u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":49757330964717,"sku":"WS3978","price":2200.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/562f0374ad4c593a2411079f966090f8.jpg?v=1775480075","url":"https:\/\/caboeletro.com\/en\/products\/detector-de-falha-de-isolamento-schneider-1518384v2","provider":"Cabo Eletro","version":"1.0","type":"link"}