{"product_id":"contator-tripolar-abb-a260-30-11-84-110-120v-60hz","title":"ABB Three-Pole Contactor A260-30-11-84 110-120V 60Hz","description":"\u003cp\u003eABB A260-30-11-84 110-120v 60Hz Three-Pole Contactor\u003c\/p\u003e\n\u003cp\u003eUsed product, out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: ABB\u003c\/p\u003e\n\u003cp\u003eModel: A260-30-11-84 1SFL531001R8411\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA three-pole contactor is an electromechanical device used to switch three-phase alternating current (AC) electrical circuits on and off. It is widely used in industrial control and automation systems to operate motors, resistors, capacitors, and other equipment that operate in three-phase systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA three-pole contactor has three poles, each corresponding to one phase of the three-phase system (R, S, T or L1, L2, L3). This allows for simultaneous control of the three phases of a three-phase circuit.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCatalog Description:\u003c\/p\u003e\n\u003cp\u003eA260-30-11 Contactor 110V 50Hz \/ 110-120V 60Hz\u003c\/p\u003e\n\u003cp\u003eLong Description:\u003c\/p\u003e\n\u003cp\u003eA 3-phase contactor suitable for various applications such as motor starting, isolation, bypass and distribution applications up to max 690 V. Operated with control voltage, versions from 24 to 0.690 AC, 50 and 60 Hz\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTechnical\u003c\/p\u003e\n\u003cp\u003eNumber of Main NO Contacts:\u003c\/p\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003cp\u003eNumber of Main NC Contacts:\u003c\/p\u003e\n\u003cp\u003e0\u003c\/p\u003e\n\u003cp\u003eNumber of Auxiliary NO Contacts:\u003c\/p\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003cp\u003eNumber of Auxiliary NC Contacts:\u003c\/p\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003cp\u003eRated Operational Voltage:\u003c\/p\u003e\n\u003cp\u003eMain Circuit 690 V\u003c\/p\u003e\n\u003cp\u003eRated Frequency (f):\u003c\/p\u003e\n\u003cp\u003eMain Circuit 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eConventional Free-Air Thermal Current (Ith):\u003c\/p\u003e\n\u003cp\u003eacc. to IEC 60947-4-1, Open Contactors 0 = 40 °C 400 A\u003c\/p\u003e\n\u003cp\u003eRated Operational Current AC-1 (Ie):\u003c\/p\u003e\n\u003cp\u003e(690 V) 40 C 400 A\u003c\/p\u003e\n\u003cp\u003e(690 V) 55 C 350 A\u003c\/p\u003e\n\u003cp\u003e(690 V) 70 C 290 A\u003c\/p\u003e\n\u003cp\u003eRated Operational Current AC-3 (Ie):\u003c\/p\u003e\n\u003cp\u003e(415 V) 55 C 260 A\u003c\/p\u003e\n\u003cp\u003e(440 V) 55 C 240 A\u003c\/p\u003e\n\u003cp\u003e(500 V) 55 C 240 A\u003c\/p\u003e\n\u003cp\u003e(690 V) 55 C 220 A\u003c\/p\u003e\n\u003cp\u003e(380\/400 V) 55 °C 260 A\u003c\/p\u003e\n\u003cp\u003e(220\/230\/240 V) 55°C 260\u003c\/p\u003e\n\u003cp\u003eRated Operational Power AC-3 (Pe):\u003c\/p\u003e\n\u003cp\u003e(415 V) 140 kW\u003c\/p\u003e\n\u003cp\u003e(440 V) 140 kW\u003c\/p\u003e\n\u003cp\u003e(500 V) 180 kW\u003c\/p\u003e\n\u003cp\u003e(690 V) 200 kW\u003c\/p\u003e\n\u003cp\u003e(380\/400 V) 140 kW\u003c\/p\u003e\n\u003cp\u003e(220\/230\/240 V) 80 kW\u003c\/p\u003e\n\u003cp\u003eRated Breaking Capacity AC-3:\u003c\/p\u003e\n\u003cp\u003e8 x Ie AC-3\u003c\/p\u003e\n\u003cp\u003eRated Making Capacity AC-3:\u003c\/p\u003e\n\u003cp\u003e10 x Ie AC-3\u003c\/p\u003e\n\u003cp\u003eShort-Circuit Protective Devices:\u003c\/p\u003e\n\u003cp\u003egG Type Fuses 500 A\u003c\/p\u003e\n\u003cp\u003eRated Short-Time Withstand Current (Icw):\u003c\/p\u003e\n\u003cp\u003eat 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A\u003c\/p\u003e\n\u003cp\u003eat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A\u003c\/p\u003e\n\u003cp\u003eat 40 °C, Ambient Temp, in Free Air, from a Cold State 1 min 1100 A\u003c\/p\u003e\n\u003cp\u003eat 40 °C, Ambient Temp, in Free Air, from a Cold State 1 s 3500 A\u003c\/p\u003e\n\u003cp\u003eat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A\u003c\/p\u003e\n\u003cp\u003eMaximum Breaking Capacity:\u003c\/p\u003e\n\u003cp\u003ecos phi=0.45 (cos phi=0.35 for Ie \u003e 100 A) at 440 V 2600 A\u003c\/p\u003e\n\u003cp\u003ecos phi=0.45 (cos phi=0.35 for Ie \u003e 100 A) at 690 V 2400 A\u003c\/p\u003e\n\u003cp\u003eMaximum Electrical Switching Frequency:\u003c\/p\u003e\n\u003cp\u003e(AC-1) 300 cycles per hour\u003c\/p\u003e\n\u003cp\u003e(AC-2 \/ AC-4) 150 cycles per hour\u003c\/p\u003e\n\u003cp\u003e(AC-3) 300 cycles per hour\u003c\/p\u003e\n\u003cp\u003eRated Operational Current DC-1 (Ie):\u003c\/p\u003e\n\u003cp\u003e(110 V) 2 Poles in Series, 40 C 400 A\u003c\/p\u003e\n\u003cp\u003e(220 V) 3 Poles in Series, 40 C 400 A\u003c\/p\u003e\n\u003cp\u003eRated Operational Current DC-3 (Ie):\u003c\/p\u003e\n\u003cp\u003e(110 V) 2 Poles in Series, 40 C 400 A\u003c\/p\u003e\n\u003cp\u003e(220 V) 3 Poles in Series, 40 C 400 A\u003c\/p\u003e\n\u003cp\u003eRated Operational Current DC-5 (Ie):\u003c\/p\u003e\n\u003cp\u003e(110 V) 2 Poles in Series, 40 C 400 A\u003c\/p\u003e\n\u003cp\u003e(220 V) 3 Poles in Series, 40 C 400 A\u003c\/p\u003e\n\u003cp\u003eRated Insulation Voltage (Ui):\u003c\/p\u003e\n\u003cp\u003eacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V\u003c\/p\u003e\n\u003cp\u003eacc. to UL\/CSA 600 V\u003c\/p\u003e\n\u003cp\u003eRated Impulse Withstand Voltage (Uimp):\u003c\/p\u003e\n\u003cp\u003eMain Circuit 8 kV\u003c\/p\u003e\n\u003cp\u003eMechanical Durability:\u003c\/p\u003e\n\u003cp\u003e5 million\u003c\/p\u003e\n\u003cp\u003eMaximum Mechanical Switching Frequency:\u003c\/p\u003e\n\u003cp\u003e3600 cycles per hour\u003c\/p\u003e\n\u003cp\u003eCoil Operating Limits:\u003c\/p\u003e\n\u003cp\u003e(according to IEC 60947-4-1) 0.85 x Uc Min ... 1.1 x Uc Max (at 0 \u003c 70 °C)\u003c\/p\u003e\n\u003cp\u003eRated Control Circuit Voltage (Uc):\u003c\/p\u003e\n\u003cp\u003e50 Hz 110 V\u003c\/p\u003e\n\u003cp\u003e60 Hz 110 ... 120 V\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 29\/05\/2024\u003c\/p\u003e\n\u003cp\u003eWeight: 6.120Kg\u003c\/p\u003e\n\u003cp\u003eMeasurements: 24x20x15\u003c\/p\u003e\n\u003cp\u003eLocator: A14P3B\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is for resale, the ST (Tax Substitution) value may apply. If the operation is subject to this tax, payment is the sole responsibility of the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial LTDA thanks you.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46605866008813,"sku":"WS4932","price":3325.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/contator-tripolar-abb-a260-30-11-84-110-120v-60hz_1.jpg?v=1782405809","url":"https:\/\/caboeletro.com\/en\/products\/abb-three-pole-contactor-a260-30-11-84-110-120v-60hz","provider":"Cabo Eletro","version":"1.0","type":"link"}