{"product_id":"disjuntor-bipolar-abb-sh202t-b16-b-16a-400v-3ka","title":"ABB SH202T-B16 B 16A 400V 3kA Double Pole Circuit Breaker","description":"\u003cp\u003eBipolar Circuit Breaker ABB SH202T-B16 B 16A 400v 3kA\u003c\/p\u003e\n\u003cp\u003eNew product out of manufacturer's box\u003c\/p\u003e\n\u003cp\u003eBrand: ABB\u003c\/p\u003e\n\u003cp\u003eModel: SH202T-B16 2CDS23001R0165\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e(Cover photo for illustration purposes only)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMiniature Circuit Breaker SH202T-B16 - 2P - B - 16 A\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA circuit breaker is an electrical protection device designed to interrupt the flow of electrical current in an electrical circuit when abnormal conditions occur, such as overloads or short circuits. It acts as a type of automatic switch that turns off the circuit when it detects an abnormally high electrical current or when there is a fault in the electrical system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCircuit breakers play a critical role in the safety of electrical installations, as they help prevent fires, equipment damage, and electrical hazards by automatically shutting off the circuit in emergency situations. They are widely used in homes, businesses, and industrial facilities.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Compact Home SH200T miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanical tripping mechanism for short-circuit protection. They are available in different characteristics (B, C), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 3 kA at 230\/400 V AC) and rated currents (up to 40 A). All MCBs in the SH200T product line comply with IEC\/EN 60898-1, allowing their use in residential applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTechnical\u003c\/p\u003e\n\u003cp\u003eStandards: IEC\/EN 60898-1\u003c\/p\u003e\n\u003cp\u003eTripping characteristic: B\u003c\/p\u003e\n\u003cp\u003eRated operational voltage: acc. to IEC 60898-1 400 V AC\u003c\/p\u003e\n\u003cp\u003eOperating voltage: Maximum (incl. tolerance) 440 V AC\u003c\/p\u003e\n\u003cp\u003eMinimum 12 V AC\u003c\/p\u003e\n\u003cp\u003eRated insulation voltage (U i ): acc. to IEC\/EN 60664-1 440 V\u003c\/p\u003e\n\u003cp\u003eRated impulse withstand voltage (U imp ): 4 kV\u003c\/p\u003e\n\u003cp\u003eat 2,000 m 5 kV\u003c\/p\u003e\n\u003cp\u003eat sea level 6.2 kV\u003c\/p\u003e\n\u003cp\u003eDielectric test voltage: 50\/60 Hz, 1 min: 2 kV\u003c\/p\u003e\n\u003cp\u003eInput voltage type: AC\u003c\/p\u003e\n\u003cp\u003eRated current (I n ): 16A\u003c\/p\u003e\n\u003cp\u003eRated short-circuit capacity: (AC) 3 kA\u003c\/p\u003e\n\u003cp\u003e(400 V AC) 3 kA\u003c\/p\u003e\n\u003cp\u003eRated conditional short-circuit current (I nc ): (230 V) 10 kA\u003c\/p\u003e\n\u003cp\u003e(400 V) 10 kA\u003c\/p\u003e\n\u003cp\u003eRated frequency (f): 50\/60Hz\u003c\/p\u003e\n\u003cp\u003ePower loss: 5 W\u003c\/p\u003e\n\u003cp\u003eat rated operating conditions per pole 2.5 W\u003c\/p\u003e\n\u003cp\u003ePower supply connection: Arbitrary\u003c\/p\u003e\n\u003cp\u003eContact position indication: ON OFF\u003c\/p\u003e\n\u003cp\u003eEnergy Limiting Class: 3\u003c\/p\u003e\n\u003cp\u003eElectrical Endurance: 20,000 AC cycle\u003c\/p\u003e\n\u003cp\u003eMechanical Endurance: 20,000 cycle\u003c\/p\u003e\n\u003cp\u003eNumber of poles: 2\u003c\/p\u003e\n\u003cp\u003eNumber of Protected Poles: 2\u003c\/p\u003e\n\u003cp\u003eOvervoltage category: III\u003c\/p\u003e\n\u003cp\u003eTightening torque: 2 N·m\u003c\/p\u003e\n\u003cp\u003eActuator type: Toggle\u003c\/p\u003e\n\u003cp\u003eScrew terminal type: Cage terminal\u003c\/p\u003e\n\u003cp\u003eActuator marking: I\/O\u003c\/p\u003e\n\u003cp\u003eActuator material: Insulation Group II, Black, Sealable\u003c\/p\u003e\n\u003cp\u003eHousing material: Insulation Group II, RAL 7035\u003c\/p\u003e\n\u003cp\u003eDIN rail mounting: TH35-15 (mounting rail 35 x 15 mm) acc. to IEC 60715\u003c\/p\u003e\n\u003cp\u003eTH35-7.5 (mounting rail 35 x 7.5 mm) acc. to IEC 60715\u003c\/p\u003e\n\u003cp\u003eMounting position: any\u003c\/p\u003e\n\u003cp\u003eRecommended screwdriver: Pozidriv 2\u003c\/p\u003e\n\u003cp\u003eAvailable accessories: No\u003c\/p\u003e\n\u003cp\u003eConnection capacity: Conductor 25 \/ 25 mm²\u003c\/p\u003e\n\u003cp\u003eFlexible with ferrule 0.75 ... 16 mm²\u003c\/p\u003e\n\u003cp\u003eFlexible 0.75 ... 16 mm²\u003c\/p\u003e\n\u003cp\u003eRigid 0.75 ... 25 mm²\u003c\/p\u003e\n\u003cp\u003eStranded 0.75 ... 25 mm²\u003c\/p\u003e\n\u003cp\u003eInstallation size: acc. to DIN 43880 1\u003c\/p\u003e\n\u003cp\u003eTerminal type: Screw terminals\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDate: 09\/05\/2023\u003c\/p\u003e\n\u003cp\u003eWeight: 0.250g\u003c\/p\u003e\n\u003cp\u003eMeasurements: 9x8x4\u003c\/p\u003e\n\u003cp\u003eLocator: B15P1A\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDear customers, if the material is for resale, the ST (Tax Substitution) value may apply. If the operation is subject to this tax, the responsibility for payment rests solely with the buyer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCabo Eletro Comercial ltda thanks you\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eML\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46626660155629,"sku":"WS1661","price":39.9,"currency_code":"BRL","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/1567\/7611\/files\/disjuntor-bipolar-abb-sh202t-b16-b-16a-400v-3ka_1.jpg?v=1782410013","url":"https:\/\/caboeletro.com\/en\/products\/abb-sh202t-b16-b-16a-400v-3ka-double-pole-circuit-breaker","provider":"Cabo Eletro","version":"1.0","type":"link"}